Product Categories

LIH(St)H-TP/TT Signal Control Cable

Product Code: LIH(St)H-TP/TT

  • Cable Construction
  • Technical Data
  • Standards
  • Types
  • Mechanical Characteristics
1 – Conductor : Stranded electrolytic copper conductor (Class 5) (IEC 60228, EN 60228, DIN VDE 0295)
2 – Insulation : Halogen-free (TS IEC 60189-2, EN 50290-2-26) (DIN 47100)
3 – Stranding : Insulations are stranded into pairs or triads and all pairs or triads are stranded together.
4 – Wrapping : Polyester tape
5 – Screen : Tinned copper earthing wire, Al/PET tape
6 – Outer Jacket : UV resistant halogen-free outer jacket. RAL 7035 (Grey)
Cross
Section
Conductor Resistance
(20 °C)
Ω/km
Insulation
Resistance
(20 °C)
MΩ/km
Mutual Capacitance

nF/km

Operating
Voltage
V DC
Test Voltage

(@ 1 minute)
V DC

0.22 mm² 85.0 200 110 250 1200
0.25 mm² 77.8 200 110 250 1200
0.34 mm² 56.0 200 110 250 1200
0.50 mm² 39.0 20 120 300/500 2000
0.75 mm² 26.0 20 120 300/500 2000
1.00 mm² 19.5 20 130 300/500 2000
1.50 mm² 13.3 20 140 300/500 2000
2.50 mm² 7.98 20 150 300/500 2000
Smoke Density Test Corrosive Gas Test Halogen-free Test Flame Propagation Test Flame Retardancy Test
IEC 61034-2,
VDE 0482-1034-2,
BS EN 61034-2
IEC 60754-2,
VDE 0482-267-2-3,
BS EN 50267-2-3
IEC 60754-1,
VDE 0482-267-2-1,
BS EN 50267-2-1
IEC 60332-3-24,
VDE 0482-332-3-24,
EN 60332-2-24
IEC 60332-1-2,
VDE 0482-332-1-2,
BS EN 60332-1-2
Part Number Conductor Count Pair Count Conductor Cross-section (mm²) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.543.2.3.3.0050.0.0001 1 0,5 5,1 11 32 100/500/1000
3.543.2.3.3.0050.0.0002 2 0,5 6,6 19,8 52 100/500/1000
3.543.2.3.3.0050.0.0003 3 0,5 7,7 28,7 70 100/500/1000
3.543.2.3.3.0050.0.0004 4 0,5 9,5 37,5 95 100/500/1000
3.543.2.3.3.0050.0.0005 5 0,5 9,9 46,4 110 100/500/1000
3.543.2.3.3.0050.0.0006 6 0,5 10,5 55,2 128 100/500/1000
3.543.2.3.3.0050.0.0007 7 0,5 11,5 64 148 100/500/1000
3.543.2.3.3.0050.0.0008 8 0,5 12 72,9 163 100/500/1000
3.543.2.3.3.0050.0.0009 9 0,5 12,7 81,7 183 100/500/1000
3.543.2.3.3.0050.0.0010 10 0,5 13,2 90,6 199 100/500/1000
Part Number Conductor Count Pair Count Conductor Cross-section (mm²) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.543.2.3.3.0075.0.0001 1 0,75 5,4 17,7 40 100/500/1000
3.543.2.3.3.0075.0.0002 2 0,75 7,3 30,9 68 100/500/1000
3.543.2.3.3.0075.0.0003 3 0,75 8,4 44,2 92 100/500/1000
3.543.2.3.3.0075.0.0004 4 0,75 10,4 57,5 124 100/500/1000
3.543.2.3.3.0075.0.0005 5 0,75 10,8 70,7 143 100/500/1000
3.543.2.3.3.0075.0.0006 6 0,75 11,5 84 166 100/500/1000
3.543.2.3.3.0075.0.0007 7 0,75 12,5 97,3 192 100/500/1000
3.543.2.3.3.0075.0.0008 8 0,75 13 110,5 213 100/500/1000
3.543.2.3.3.0075.0.0009 9 0,75 13,8 123,8 237 100/500/1000
3.543.2.3.3.0075.0.0010 10 0,75 14,4 137,1 259 100/500/1000
Part Number Conductor Count Pair Count Conductor Cross-section (mm²) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.543.2.3.3.0100.0.0001 1 1 5,8 21 46 100/500/1000
3.543.2.3.3.0100.0.0002 2 1 7,9 37,6 79 100/500/1000
3.543.2.3.3.0100.0.0003 3 1 9,1 54,1 109 100/500/1000
3.543.2.3.3.0100.0.0004 4 1 11,2 70,7 145 100/500/1000
3.543.2.3.3.0100.0.0005 5 1 11,7 87,3 169 100/500/1000
3.543.2.3.3.0100.0.0006 6 1 12,5 103,9 197 100/500/1000
3.543.2.3.3.0100.0.0007 7 1 13,6 120,5 228 100/500/1000
3.543.2.3.3.0100.0.0008 8 1 14,2 137,1 252 100/500/1000
3.543.2.3.3.0100.0.0009 9 1 15 153,7 282 100/500/1000
3.543.2.3.3.0100.0.0010 10 1 15,6 170,2 308 100/500/1000
Part Number Conductor Count Pair Count Conductor Cross-section (mm²) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.543.2.3.3.0150.0.0001 1 1,5 6,7 30,2 63 100/500/1000
3.543.2.3.3.0150.0.0002 2 1,5 8,8 56,1 105 100/500/1000
3.543.2.3.3.0150.0.0003 3 1,5 10,3 81,9 146 100/500/1000
3.543.2.3.3.0150.0.0004 4 1,5 12,6 107,8 194 100/500/1000
3.543.2.3.3.0150.0.0005 5 1,5 13,2 133,6 229 100/500/1000
3.543.2.3.3.0150.0.0006 6 1,5 14 159,4 268 100/500/1000
3.543.2.3.3.0150.0.0007 7 1,5 15,3 185,3 310 100/500/1000
3.543.2.3.3.0150.0.0008 8 1,5 16 211,1 345 100/500/1000
3.543.2.3.3.0150.0.0009 9 1,5 16,9 237 386 100/500/1000
3.543.2.3.3.0150.0.0010 10 1,5 17,6 262,8 422 100/500/1000
Part Number Conductor Count Pair Count Conductor Cross-section (mm²) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.543.2.3.3.0250.0.0001 1 2,5 7,9 47,5 89 100/500/1000
3.543.2.3.3.0250.0.0002 2 2,5 10,6 90,5 153 100/500/1000
3.543.2.3.3.0250.0.0003 3 2,5 12,4 133,6 215 100/500/1000
3.543.2.3.3.0250.0.0004 4 2,5 15,2 176,7 287 100/500/1000
3.543.2.3.3.0250.0.0005 5 2,5 16 219,7 343 100/500/1000
3.543.2.3.3.0250.0.0006 6 2,5 17 262,8 403 100/500/1000
3.543.2.3.3.0250.0.0007 7 2,5 18,6 305,9 468 100/500/1000
3.543.2.3.3.0250.0.0008 8 2,5 19,3 349 524 100/500/1000
3.543.2.3.3.0250.0.0009 9 2,5 20,5 392 586 100/500/1000
3.543.2.3.3.0250.0.0010 10 2,5 21,4 435,1 644 100/500/1000
Bending Radius Temperature Range
Operating
7.5xD mm -30°C ~ +70°C