Product Categories

A-2Y(L)2Y Outdoor Telephone Cable

Product Code: PD-AP

  • Cable Construction
  • Technical Data
  • Types
1 – Conductor : Electrolytic annealed solid copper (CCITT Yellow Book Vol. III-2-G.541 B article, IEC 28 and ASTM B 3).
2 – Insulation : Color coded solid polyethylene insulation (BS 6234 Type 03 – ASTM D 1248).
3 – Stranding : Star quads or pairs are assembled into 10 pairs units. Groups having 25, 50 or 100 pairs are stranded together.
4 – Wrapping : A non-hygroscopic and dielectric polyester tape is applied on the cable core longitudinally or helically.
5 – Screen : Both sides are coated with copolymer coated flat aluminum tape over cable core longitudinally for screening.
6 – Outer Jacket : Linear low-density or medium-density, UV resistant black polyethylene outer jacket (ASTM D 1248).
Conductor Diameter
0.40 mm  0.50 mm  0.60 mm  0.63 mm  0.65 mm  0.80 mm  0.90 mm
Conductor Resistance Ω/km (20 °C)
Maximum Average 139,4 89,4 62,1 58 57 35 27,6
Maximum Individual 146,6 93 64,6 60 58 37 28,8
Insulation Resistance MΩ/km (500 VDC)  >10000 >10000 >15000 >15000 >15000 >15000 >15000
Mutual Capacitance nF/km (800 Hz)
Maximum Average 50 50 45 45 45 45 45
Maximum Individual 56 56 51 51 51 51 51
Capacitance Unbalance pF/500 m
Between Pairs
Maximum Average 125 125 60 60 60 60 60
Maximum Individual 350 350 325 325 325 325 325
Between Adjacent Quads
Maximum Average 125 125 60 60 60 60 60
Maximum Individual 275 275 270 270 270 270 270
To Screen
Maximum Average 500 500 325 325 325 325 325
Maximum Individual 2000 2000 1300 1300 1300 1300 1300
Dielectric Strength
V (DC, 1 minute)
Pair – Pair 1400 1400 2000 2000 2000 2400 3000
Pair – Screen 1400 1400 2000 2000 2000 2400 3000
PD-AP (Quad)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.161.4.1.1.0040.0.0002 2 0,4 6,2 4,8 38 1000/2000
3.161.4.1.1.0040.0.0004 4 0,4 6,3 9,5 44 1000/2000
3.161.4.1.1.0040.0.0006 6 0,4 7,3 14,3 56 1000/2000
3.161.4.1.1.0040.0.0010 10 0,4 7,9 23,7 74 1000/2000
3.161.4.1.1.0040.0.0020 20 0,4 9,5 47,4 114 1000/2000
3.161.4.1.1.0040.0.0030 30 0,4 11,8 71,1 158 1200
3.161.4.1.1.0040.0.0040 40 0,4 12,6 94,8 192 1200
3.161.4.1.1.0040.0.0050 50 0,4 13,6 118,5 229 1200
3.161.4.1.1.0040.0.0070 70 0,4 14,9 165,9 296 1200
3.161.4.1.1.0040.0.0080 80 0,4 15,8 189,6 329 1200
3.161.4.1.1.0040.0.0100 100 0,4 17,4 241,6 404 1200
3.161.4.1.1.0040.0.0150 150 0,4 21,3 362,4 581 1000
3.161.4.1.1.0040.0.0200 200 0,4 23,3 483,2 744 1000
3.161.4.1.1.0040.0.0250 250 0,4 28,1 604 943 1000
3.161.4.1.1.0040.0.0300 300 0,4 28,1 724,8 1090 1000
3.161.4.1.1.0040.0.0350 350 0,4 28,9 845,5 1246 1000
3.161.4.1.1.0040.0.0400 400 0,4 31,1 966,3 1409 500
3.161.4.1.1.0040.0.0500 500 0,4 35,2 1207,9 1740 500
3.161.4.1.1.0040.0.0600 600 0,4 38,3 1449,5 2080 500
3.161.4.1.1.0040.0.0700 700 0,4 40,2 1691 2401 400
3.161.4.1.1.0040.0.0800 800 0,4 42,8 1932,6 2728 400
3.161.4.1.1.0040.0.0900 900 0,4 46,5 2174,2 3055 400
3.161.4.1.1.0040.0.1000 1000 0,4 49,1 2415,8 3401 400
3.161.4.1.1.0040.0.1200 1200 0,4 52,6 2898,9 4038 300
3.161.4.1.1.0040.0.1500 1500 0,4 59,4 3623,6 5054 300
3.161.4.1.1.0040.0.1600 1600 0,4 69,3 3865,2 5476 250
3.161.4.1.1.0040.0.1800 1800 0,4 65,2 4348,3 6018 250
3.161.4.1.1.0040.0.2100 2100 0,4 69,3 5073 6952 250
3.161.4.1.1.0040.0.2400 2400 0,4 72 5797,8 7869 250
PD-AP (Quad)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.161.4.1.1.0050.0.0002 2 0,5 6,6 7,5 45 1000/2000
3.161.4.1.1.0050.0.0004 4 0,5 6,7 14,9 54 1000/2000
3.161.4.1.1.0050.0.0006 6 0,5 7,9 22,3 68 1000/2000
3.161.4.1.1.0050.0.0010 10 0,5 8,5 37,1 93 1000/2000
3.161.4.1.1.0050.0.0020 20 0,5 10,4 74,1 149 1200
3.161.4.1.1.0050.0.0030 30 0,5 13,1 111,1 210 1200
3.161.4.1.1.0050.0.0040 40 0,5 14,1 148,1 261 1200
3.161.4.1.1.0050.0.0050 50 0,5 15,2 185,2 314 1200
3.161.4.1.1.0050.0.0070 70 0,5 16,8 259,2 412 1200
3.161.4.1.1.0050.0.0080 80 0,5 19,5 296,2 474 1200
3.161.4.1.1.0050.0.0100 100 0,5 19,8 377,5 572 1200
3.161.4.1.1.0050.0.0150 150 0,5 24,3 566,2 827 1000
3.161.4.1.1.0050.0.0200 200 0,5 26,7 755 1068 1000
3.161.4.1.1.0050.0.0250 250 0,5 29,6 943,7 1331 1000
3.161.4.1.1.0050.0.0300 300 0,5 32,2 1132,4 1574 500
3.161.4.1.1.0050.0.0350 350 0,5 35,5 1321,1 1823 500
3.161.4.1.1.0050.0.0400 400 0,5 35,8 1509,9 2047 500
3.161.4.1.1.0050.0.0500 500 0,5 40,6 1887,3 2532 400
3.161.4.1.1.0050.0.0600 600 0,5 44,2 2264,8 3029 400
3.161.4.1.1.0050.0.0700 700 0,5 46,4 2642,2 3504 400
3.161.4.1.1.0050.0.0800 800 0,5 49,5 3019,7 3990 400
3.161.4.1.1.0050.0.0900 900 0,5 53,7 3397,1 4475 300
3.161.4.1.1.0050.0.1000 1000 0,5 56,7 3774,6 4978 300
3.161.4.1.1.0050.0.1200 1200 0,5 60,8 4529,5 5923 300
3.161.4.1.1.0050.0.1500 1500 0,5 68,8 5661,9 7412 250
3.161.4.1.1.0050.0.1600 1600 0,5 70,7 6039,3 7896 250
3.161.4.1.1.0050.0.1800 1800 0,5 75,5 6794,2 8842 250
PD-AP (Quad)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.161.4.1.1.0060.0.0002 2 0,6 7,3 10,7 52 1000/2000
3.161.4.1.1.0060.0.0004 4 0,6 7,5 21,4 67 1000/2000
3.161.4.1.1.0060.0.0006 6 0,6 9 32 89 1000/2000
3.161.4.1.1.0060.0.0010 10 0,6 9,7 53,4 122 1000/2000
3.161.4.1.1.0060.0.0020 20 0,6 12,1 106,7 204 1200
3.161.4.1.1.0060.0.0030 30 0,6 15,6 160 293 1200
3.161.4.1.1.0060.0.0040 40 0,6 16,9 213,3 368 1200
3.161.4.1.1.0060.0.0050 50 0,6 18,4 266,6 442 1200
3.161.4.1.1.0060.0.0070 70 0,6 20,4 373,2 587 1000
3.161.4.1.1.0060.0.0100 100 0,6 24,2 543,6 821 1000
3.161.4.1.1.0060.0.0150 150 0,6 30 815,4 1202 1000
3.161.4.1.1.0060.0.0200 200 0,6 33,1 1087,1 1557 500
3.161.4.1.1.0060.0.0250 250 0,6 36,8 1358,9 1944 500
3.161.4.1.1.0060.0.0300 300 0,6 40 1630,7 2302 500
3.161.4.1.1.0060.0.0350 350 0,6 41,5 1902,4 2648 400
3.161.4.1.1.0060.0.0400 400 0,6 44,7 2174,2 3006 400
3.161.4.1.1.0060.0.0500 500 0,6 50,9 2717,7 3725 300
3.161.4.1.1.0060.0.0600 600 0,6 55,5 3261,3 4456 300
3.161.4.1.1.0060.0.0700 700 0,6 58,2 3804,8 5163 300
3.161.4.1.1.0060.0.0900 900 0,6 67,7 4891,9 6599 250
3.161.4.1.1.0060.0.1000 1000 0,6 71,5 5435,4 7338 250
3.161.4.1.1.0060.0.1200 1200 0,6 76,8 6522,5 8743 250
PD-AP (Quad)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.161.4.1.1.0080.0.0002 2 0,8 8,5 19 70 1000/2000
3.161.4.1.1.0080.0.0004 4 0,8 8,6 38 95 1000/2000
3.161.4.1.1.0080.0.0006 6 0,8 10,7 56,9 131 1200
3.161.4.1.1.0080.0.0010 10 0,8 11,5 94,8 188 1200
3.161.4.1.1.0080.0.0020 20 0,8 14,9 189,6 329 1200
3.161.4.1.1.0080.0.0030 30 0,8 19,5 284,4 475 1200
3.161.4.1.1.0080.0.0040 40 0,8 21,4 379,2 608 1000
3.161.4.1.1.0080.0.0050 50 0,8 23,4 473,9 738 1000
3.161.4.1.1.0080.0.0070 70 0,8 26,2 663,5 993 1000
3.161.4.1.1.0080.0.0100 100 0,8 31,4 966,3 1403 500
3.161.4.1.1.0080.0.0150 150 0,8 39,2 1449,5 2066 500
3.161.4.1.1.0080.0.0200 200 0,8 43,4 1932,6 2692 400
3.161.4.1.1.0080.0.0300 300 0,8 52,6 2898,9 4000 300
3.161.4.1.1.0080.0.0400 400 0,8 59,1 3865,2 5249 300
3.161.4.1.1.0080.0.0500 500 0,8 67,5 4831,5 6518 250
3.161.4.1.1.0080.0.0600 600 0,8 73,6 5797,8 7807 250
PD-AP (Quad)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.161.4.1.1.0090.0.0002 2 0,9 8,9 24 79 1000/2000
3.161.4.1.1.0090.0.0004 4 0,9 9,1 48 109 1000/2000
3.161.4.1.1.0090.0.0006 6 0,9 11,4 72 152 1200
3.161.4.1.1.0090.0.0010 10 0,9 12,2 120 221 1200
3.161.4.1.1.0090.0.0020 20 0,9 15,9 240 393 1200
3.161.4.1.1.0090.0.0030 30 0,9 21 359,9 573 1000
3.161.4.1.1.0090.0.0040 40 0,9 23 479,9 736 1000
3.161.4.1.1.0090.0.0050 50 0,9 25,3 599,8 896 1000
3.161.4.1.1.0090.0.0070 70 0,9 28,3 839,7 1211 1000
3.161.4.1.1.0090.0.0100 100 0,9 34,1 1223 1720 500
3.161.4.1.1.0090.0.0150 150 0,9 42,7 1834,5 2536 400
3.161.4.1.1.0090.0.0200 200 0,9 47,3 2446 3317 400
3.161.4.1.1.0090.0.0300 300 0,9 57,4 3668,9 4931 300
3.161.4.1.1.0090.0.0400 400 0,9 64,4 4891,9 6482 300
3.161.4.1.1.0090.0.0500 500 0,9 73,7 6114,8 8056 250
3.161.4.1.1.0090.0.0600 600 0,9 80,4 7337,8 9651 200
PD-AP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.163.1.1.1.0040.0.0002 2 0,4 6 4,8 38 1000/2000
3.163.1.1.1.0040.0.0004 4 0,4 7 9,5 50 1000/2000
3.163.1.1.1.0040.0.0006 6 0,4 7,9 14,3 61 1000/2000
3.163.1.1.1.0040.0.0010 10 0,4 8,6 23,7 80 1000/2000
3.163.1.1.1.0040.0.0020 20 0,4 10,5 47,4 125 1200
3.163.1.1.1.0040.0.0030 30 0,4 12,9 71,1 172 1200
3.163.1.1.1.0040.0.0040 40 0,4 13,9 94,8 211 1200
3.163.1.1.1.0040.0.0050 50 0,4 15,1 118,5 251 1200
3.163.1.1.1.0040.0.0070 70 0,4 16,6 165,9 323 1200
3.163.1.1.1.0040.0.0100 100 0,4 19,5 241,6 445 1200
3.163.1.1.1.0040.0.0150 150 0,4 24 362,4 637 1000
3.163.1.1.1.0040.0.0200 200 0,4 26,5 483,2 819 1000
PD-AP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.163.1.1.1.0050.0.0002 2 0,5 6,5 7,5 43 1000/2000
3.163.1.1.1.0050.0.0004 4 0,5 7,6 14,9 59 1000/2000
3.163.1.1.1.0050.0.0006 6 0,5 8,7 22,3 77 1000/2000
3.163.1.1.1.0050.0.0010 10 0,5 9,5 37,1 104 1000/2000
3.163.1.1.1.0050.0.0020 20 0,5 11,8 74,1 167 1200
3.163.1.1.1.0050.0.0030 30 0,5 14,8 111,1 234 1200
3.163.1.1.1.0050.0.0040 40 0,5 16 148,1 291 1200
3.163.1.1.1.0050.0.0050 50 0,5 17,4 185,2 349 1200
3.163.1.1.1.0050.0.0070 70 0,5 15,2 259,2 432 1200
3.163.1.1.1.0050.0.0100 100 0,5 22,8 377,5 634 1000
3.163.1.1.1.0050.0.0150 150 0,5 28,2 566,2 923 1000
3.163.1.1.1.0050.0.0200 200 0,5 31,3 755 1194 500
PD-AP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.163.1.1.1.0060.0.0002 2 0,6 7,4 10,7 55 1000/2000
3.163.1.1.1.0060.0.0004 4 0,6 8,9 21,4 81 1000/2000
3.163.1.1.1.0060.0.0006 6 0,6 10,6 32 105 1200
3.163.1.1.1.0060.0.0010 10 0,6 11,4 53,4 145 1200
3.163.1.1.1.0060.0.0020 20 0,6 14,7 106,7 244 1200
3.163.1.1.1.0060.0.0030 30 0,6 18,8 160 350 1200
3.163.1.1.1.0060.0.0040 40 0,6 20,6 213,3 439 1000
3.163.1.1.1.0060.0.0050 50 0,6 22,5 266,6 528 1000
3.163.1.1.1.0060.0.0070 70 0,6 25,1 373,2 702 1000
3.163.1.1.1.0060.0.0080 80 0,6 26,9 426,6 805 1000
3.163.1.1.1.0060.0.0100 100 0,6 30,5 543,6 1000 500
3.163.1.1.1.0060.0.0150 150 0,6 38,2 815,4 1466 500
3.163.1.1.1.0060.0.0200 200 0,6 42,2 1087,1 1892 400
PD-AP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.163.1.1.1.0063.0.0002 2 0,63 7,6 11,8 59 1000/2000
3.163.1.1.1.0063.0.0004 4 0,63 9,3 23,6 86 1000/2000
3.163.1.1.1.0063.0.0006 6 0,63 11 35,3 114 1200
3.163.1.1.1.0063.0.0010 10 0,63 11,9 58,8 158 1200
3.163.1.1.1.0063.0.0020 20 0,63 15,4 117,6 270 1200
3.163.1.1.1.0063.0.0030 30 0,63 19,9 176,4 386 1200
3.163.1.1.1.0063.0.0040 40 0,63 21,7 235,2 485 1000
3.163.1.1.1.0063.0.0050 50 0,63 23,8 293,9 584 1000
3.163.1.1.1.0063.0.0070 70 0,63 26,6 411,5 777 1000
3.163.1.1.1.0063.0.0100 100 0,63 32,4 599,3 1107 500
3.163.1.1.1.0063.0.0150 150 0,63 40,5 898,9 1628 400
3.163.1.1.1.0063.0.0200 200 0,63 45 1198,5 2114 400
PD-AP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.163.1.1.1.0065.0.0002 2 0,65 7,8 12,6 61 1000/2000
3.163.1.1.1.0065.0.0004 4 0,65 9,6 25,1 91 1000/2000
3.163.1.1.1.0065.0.0006 6 0,65 11,5 37,6 122 1200
3.163.1.1.1.0065.0.0010 10 0,65 12,4 62,6 169 1200
3.163.1.1.1.0065.0.0020 20 0,65 16,2 125,2 289 1200
3.163.1.1.1.0065.0.0030 30 0,65 20,9 187,8 416 1000
3.163.1.1.1.0065.0.0040 40 0,65 22,9 250,3 523 1000
3.163.1.1.1.0065.0.0050 50 0,65 25,1 312,9 634 1000
3.163.1.1.1.0065.0.0070 70 0,65 28,9 438 848 1000
3.163.1.1.1.0065.0.0100 100 0,65 35,2 637,9 1208 500
3.163.1.1.1.0065.0.0150 150 0,65 42,9 956,9 1770 400
3.163.1.1.1.0065.0.0200 200 0,65 47,6 1275,8 2303 400
PD-AP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.163.1.1.1.0080.0.0002 2 0,8 8,3 19 72 1000/2000
3.163.1.1.1.0080.0.0004 4 0,8 10,3 38 111 1200
3.163.1.1.1.0080.0.0006 6 0,8 12,4 56,9 151 1200
3.163.1.1.1.0080.0.0010 10 0,8 13,4 94,8 214 1200
3.163.1.1.1.0080.0.0020 20 0,8 17,6 189,6 376 1200
3.163.1.1.1.0080.0.0030 30 0,8 22,9 284,4 544 1000
3.163.1.1.1.0080.0.0040 40 0,8 25,1 379,2 694 1000
3.163.1.1.1.0080.0.0050 50 0,8 27,6 473,9 842 1000
3.163.1.1.1.0080.0.0070 70 0,8 31 663,5 1131 500
3.163.1.1.1.0080.0.0100 100 0,8 37,8 966,3 1622 500
3.163.1.1.1.0080.0.0150 150 0,8 47,6 1449,5 2397 400
PD-AP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.163.1.1.1.0090.0.0002 2 0,9 8,5 24 79 1000/2000
3.163.1.1.1.0090.0.0004 4 0,9 10,6 48 123 1200
3.163.1.1.1.0090.0.0006 6 0,9 12,9 72 169 1200
3.163.1.1.1.0090.0.0010 10 0,9 13,9 120 245 1200
3.163.1.1.1.0090.0.0020 20 0,9 18,3 240 435 1200
3.163.1.1.1.0090.0.0030 30 0,9 23,9 359,9 635 1000
3.163.1.1.1.0090.0.0040 40 0,9 26,3 479,9 813 1000
3.163.1.1.1.0090.0.0050 50 0,9 29,3 599,8 1006 1000
3.163.1.1.1.0090.0.0070 70 0,9 32,7 839,7 1344 500
3.163.1.1.1.0090.0.0100 100 0,9 40,3 1223 1955 400