A-02YS(L)T2Y Outdoor Telephone Cable
Product Code: KPD-AP-A
| 1 – Conductor | : | Electrolytic annealed solid copper (CCITT Yellow Book Vol. III-2-G.541 B article, IEC 28 and ASTM B 3). |
| 2 – Insulation | : | Color coded foam skin polyethylene cladded with solid polyethylene (BS 6234 Type 03 – ASTM D 1248). |
| 3 – Stranding | : | Star quads or pairs are assembled into 10 pairs units. Groups having 25, 50 or 100 pairs are stranded together. |
| 4 – Wrapping | : | A non-hygroscopic and dielectric polyester tape is applied on the cable core longitudinally or helically. |
| 5 – Screen | : | Both sides are coated with copolymer coated flat aluminum tape over cable core longitudinally for screening. |
| 6 – Messenger Wire | : | Galvanized steel messenger wire (ASTM A 475-66T). |
| 7 – Outer Jacket | : | Linear low-density or medium-density, UV resistant black polyethylene outer jacket (ASTM D 1248). |
| Conductor Diameter | |||||||
|---|---|---|---|---|---|---|---|
| 0.40 mm | 0.50 mm | 0.60 mm | 0.63 mm | 0.65 mm | 0.80 mm | 0.90 mm | |
| Conductor Resistance Ω/km (20 °C) | |||||||
| Maximum Average | 139,4 | 89,4 | 62,1 | 58 | 57 | 35 | 27,6 |
| Maximum Individual | 146,6 | 93 | 64,6 | 60 | 58 | 37 | 28,8 |
| Insulation Resistance MΩ/km (500 VDC) | >10000 | >10000 | >15000 | >15000 | >15000 | >15000 | >15000 |
| Mutual Capacitance nF/km (800 Hz) | |||||||
| Maximum Average | 50 | 50 | 45 | 45 | 45 | 45 | 45 |
| Maximum Individual | 56 | 56 | 51 | 51 | 51 | 51 | 51 |
| Capacitance Unbalance pF/500 m | |||||||
| Between Pairs | |||||||
| Maximum Average | 125 | 125 | 60 | 60 | 60 | 60 | 60 |
| Maximum Individual | 350 | 350 | 325 | 325 | 325 | 325 | 325 |
| Between Adjacent Quads | |||||||
| Maximum Average | 125 | 125 | 60 | 60 | 60 | 60 | 60 |
| Maximum Individual | 275 | 275 | 270 | 270 | 270 | 270 | 270 |
| To Screen | |||||||
| Maximum Average | 500 | 500 | 325 | 325 | 325 | 325 | 325 |
| Maximum Individual | 2000 | 2000 | 1300 | 1300 | 1300 | 1300 | 1300 |
| Dielectric Strength | |||||||
| V (DC, 1 minute) | |||||||
| Pair – Pair | 1400 | 1400 | 2000 | 2000 | 2000 | 2400 | 3000 |
| Pair – Screen | 1400 | 1400 | 2000 | 2000 | 2000 | 2400 | 3000 |
| KPD-AP-A (Quad) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.4.5.1.0040.0.0002 | – | 2 | 0,4 | 5,8 | 4,8 | 89 | 1000/2000 | |
| 3.130.4.5.1.0040.0.0004 | – | 4 | 0,4 | 6,2 | 9,5 | 96 | 1000/2000 | |
| 3.130.4.5.1.0040.0.0006 | – | 6 | 0,4 | 7,1 | 14,3 | 107 | 1000/2000 | |
| 3.130.4.5.1.0040.0.0010 | – | 10 | 0,4 | 7,3 | 23,7 | 118 | 1000/2000 | |
| 3.130.4.5.1.0040.0.0020 | – | 20 | 0,4 | 9,2 | 47,4 | 172 | 1000/2000 | |
| 3.130.4.5.1.0040.0.0030 | – | 30 | 0,4 | 11,4 | 71,1 | 213 | 1200 | |
| 3.130.4.5.1.0040.0.0040 | – | 40 | 0,4 | 12,2 | 94,8 | 245 | 1200 | |
| 3.130.4.5.1.0040.0.0050 | – | 50 | 0,4 | 13 | 118,5 | 297 | 1200 | |
| 3.130.4.5.1.0040.0.0070 | – | 70 | 0,4 | 14,3 | 165,9 | 360 | 1200 | |
| 3.130.4.5.1.0040.0.0080 | – | 80 | 0,4 | 15,1 | 189,6 | 394 | 1200 | |
| 3.130.4.5.1.0040.0.0100 | – | 100 | 0,4 | 16,7 | 241,6 | 488 | 1200 | |
| 3.130.4.5.1.0040.0.0150 | – | 150 | 0,4 | 19,9 | 362,4 | 682 | 1200 | |
| 3.130.4.5.1.0040.0.0200 | – | 200 | 0,4 | 22 | 483,2 | 904 | 1000 | |
| KPD-AP-A (Quad) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.4.5.1.0050.0.0002 | – | 2 | 0,5 | 6,1 | 7,5 | 93 | 1000/2000 | |
| 3.130.4.5.1.0050.0.0004 | – | 4 | 0,5 | 6,6 | 14,9 | 105 | 1000/2000 | |
| 3.130.4.5.1.0050.0.0006 | – | 6 | 0,5 | 7,7 | 22,3 | 119 | 1000/2000 | |
| 3.130.4.5.1.0050.0.0010 | – | 10 | 0,5 | 7,9 | 37,1 | 147 | 1000/2000 | |
| 3.130.4.5.1.0050.0.0020 | – | 20 | 0,5 | 10,1 | 74,1 | 206 | 1200 | |
| 3.130.4.5.1.0050.0.0030 | – | 30 | 0,5 | 12,6 | 111,1 | 263 | 1200 | |
| 3.130.4.5.1.0050.0.0040 | – | 40 | 0,5 | 13,5 | 148,1 | 309 | 1200 | |
| 3.130.4.5.1.0050.0.0050 | – | 50 | 0,5 | 14,5 | 185,2 | 377 | 1200 | |
| 3.130.4.5.1.0050.0.0070 | – | 70 | 0,5 | 16 | 259,2 | 493 | 1200 | |
| 3.130.4.5.1.0050.0.0080 | – | 80 | 0,5 | 17 | 296,2 | 542 | 1200 | |
| 3.130.4.5.1.0050.0.0100 | – | 100 | 0,5 | 19,1 | 377,5 | 651 | 1200 | |
| 3.130.4.5.1.0050.0.0150 | – | 150 | 0,5 | 22,8 | 566,2 | 919 | 1000 | |
| 3.130.4.5.1.0050.0.0200 | – | 200 | 0,5 | 25,1 | 755 | 1213 | 1000 | |
| KPD-AP-A (Quad) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.4.5.1.0060.0.0002 | – | 2 | 0,6 | 6,8 | 10,7 | 102 | 1000/2000 | |
| 3.130.4.5.1.0060.0.0004 | – | 4 | 0,6 | 7,5 | 21,4 | 118 | 1000/2000 | |
| 3.130.4.5.1.0060.0.0006 | – | 6 | 0,6 | 9 | 32 | 140 | 1000/2000 | |
| 3.130.4.5.1.0060.0.0010 | – | 10 | 0,6 | 9,5 | 53,4 | 179 | 1000/2000 | |
| 3.130.4.5.1.0060.0.0020 | – | 20 | 0,6 | 12,1 | 106,7 | 281 | 1200 | |
| 3.130.4.5.1.0060.0.0030 | – | 30 | 0,6 | 15,6 | 160 | 391 | 1200 | |
| 3.130.4.5.1.0060.0.0040 | – | 40 | 0,6 | 16,9 | 213,3 | 462 | 1200 | |
| 3.130.4.5.1.0060.0.0050 | – | 50 | 0,6 | 18,3 | 266,6 | 560 | 1200 | |
| 3.130.4.5.1.0060.0.0070 | – | 70 | 0,6 | 20,4 | 373,2 | 698 | 1000 | |
| 3.130.4.5.1.0060.0.0080 | – | 80 | 0,6 | 21,7 | 426,6 | 768 | 1000 | |
| 3.130.4.5.1.0060.0.0100 | – | 100 | 0,6 | 24,4 | 543,6 | 997 | 1000 | |
| 3.130.4.5.1.0060.0.0150 | – | 150 | 0,6 | 30,1 | 815,4 | 1373 | 500 | |
| 3.130.4.5.1.0060.0.0200 | – | 200 | 0,6 | 33,2 | 1087,1 | 1785 | 500 | |
| KPD-AP-A (Quad) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.4.5.1.0080.0.0002 | – | 2 | 0,8 | 7,7 | 19 | 127 | 1000/2000 | |
| 3.130.4.5.1.0080.0.0004 | – | 4 | 0,8 | 8,5 | 38 | 154 | 1000/2000 | |
| 3.130.4.5.1.0080.0.0006 | – | 6 | 0,8 | 10,5 | 56,9 | 187 | 1200 | |
| 3.130.4.5.1.0080.0.0010 | – | 10 | 0,8 | 11,1 | 94,8 | 236 | 1200 | |
| 3.130.4.5.1.0080.0.0020 | – | 20 | 0,8 | 14,5 | 189,6 | 390 | 1200 | |
| 3.130.4.5.1.0080.0.0030 | – | 30 | 0,8 | 19 | 284,4 | 554 | 1200 | |
| 3.130.4.5.1.0080.0.0040 | – | 40 | 0,8 | 20,8 | 379,2 | 674 | 1000 | |
| 3.130.4.5.1.0080.0.0050 | – | 50 | 0,8 | 22,7 | 473,9 | 820 | 1000 | |
| 3.130.4.5.1.0080.0.0070 | – | 70 | 0,8 | 25,4 | 663,5 | 1058 | 1000 | |
| 3.130.4.5.1.0080.0.0080 | – | 80 | 0,8 | 27,1 | 758,3 | 1177 | 1000 | |
| 3.130.4.5.1.0080.0.0100 | – | 100 | 0,8 | 30,7 | 966,3 | 1517 | 500 | |
| 3.130.4.5.1.0080.0.0150 | – | 150 | 0,8 | 37,8 | 1449,5 | 2129 | 500 | |
| 3.130.4.5.1.0080.0.0200 | – | 200 | 0,8 | 42 | 1932,6 | 2795 | 400 | |
| KPD-AP-A (Quad) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.4.5.1.0090.0.0002 | – | 2 | 0,9 | 7,9 | 24 | 133 | 1000/2000 | |
| 3.130.4.5.1.0090.0.0004 | – | 4 | 0,9 | 8,8 | 48 | 167 | 1000/2000 | |
| 3.130.4.5.1.0090.0.0006 | – | 6 | 0,9 | 10,9 | 72 | 207 | 1200 | |
| 3.130.4.5.1.0090.0.0010 | – | 10 | 0,9 | 11,6 | 120 | 265 | 1200 | |
| 3.130.4.5.1.0090.0.0020 | – | 20 | 0,9 | 15,2 | 240 | 473 | 1200 | |
| 3.130.4.5.1.0090.0.0030 | – | 30 | 0,9 | 20 | 359,9 | 667 | 1200 | |
| 3.130.4.5.1.0090.0.0040 | – | 40 | 0,9 | 21,9 | 479,9 | 813 | 1000 | |
| 3.130.4.5.1.0090.0.0050 | – | 50 | 0,9 | 24 | 599,8 | 1027 | 1000 | |
| 3.130.4.5.1.0090.0.0070 | – | 70 | 0,9 | 26,9 | 839,7 | 1316 | 1000 | |
| 3.130.4.5.1.0090.0.0080 | – | 80 | 0,9 | 28,7 | 959,7 | 1462 | 1000 | |
| 3.130.4.5.1.0090.0.0100 | – | 100 | 0,9 | 32,5 | 1223 | 1862 | 500 | |
| 3.130.4.5.1.0090.0.0150 | – | 150 | 0,9 | 40,4 | 1834,5 | 2604 | 400 | |
| 3.130.4.5.1.0090.0.0200 | – | 200 | 0,9 | 44,7 | 2446 | 3316 | 400 | |
| KPD-AP-A (Pair) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.1.5.1.0040.1.0002 | – | 2 | 0,4 | 5,8 | 4,8 | 89 | 1000/2000 | |
| 3.130.1.5.1.0040.1.0004 | – | 4 | 0,4 | 6,6 | 9,5 | 100 | 1000/2000 | |
| 3.130.1.5.1.0040.1.0005 | – | 5 | 0,4 | 6,7 | 11,9 | 103 | 1000/2000 | |
| 3.130.1.5.1.0040.1.0006 | – | 6 | 0,4 | 7,5 | 14,3 | 109 | 1000/2000 | |
| 3.130.1.5.1.0040.1.0010 | – | 10 | 0,4 | 8,1 | 23,7 | 137 | 1000/2000 | |
| 3.130.1.5.1.0040.1.0020 | – | 20 | 0,4 | 9,8 | 47,4 | 178 | 1000/2000 | |
| 3.130.1.5.1.0040.1.0025 | – | 25 | 0,4 | 10,9 | 59,3 | 194 | 1200 | |
| 3.130.1.5.1.0040.1.0030 | – | 30 | 0,4 | 11,9 | 71,1 | 218 | 1200 | |
| 3.130.1.5.1.0040.1.0040 | – | 40 | 0,4 | 12,8 | 94,8 | 272 | 1200 | |
| 3.130.1.5.1.0040.1.0050 | – | 50 | 0,4 | 13,8 | 118,5 | 308 | 1200 | |
| 3.130.1.5.1.0040.1.0070 | – | 70 | 0,4 | 15,2 | 165,9 | 397 | 1200 | |
| 3.130.1.5.1.0040.1.0080 | – | 80 | 0,4 | 16 | 189,6 | 429 | 1200 | |
| 3.130.1.5.1.0040.1.0100 | – | 100 | 0,4 | 17,7 | 241,6 | 501 | 1200 | |
| 3.130.1.5.1.0040.1.0150 | – | 150 | 0,4 | 21,7 | 362,4 | 702 | 1000 | |
| 3.130.1.5.1.0040.1.0200 | – | 200 | 0,4 | 23,9 | 483,2 | 930 | 1000 | |
| KPD-AP-A (Pair) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.1.5.1.0050.1.0002 | – | 2 | 0,5 | 6,1 | 7,5 | 93 | 1000/2000 | |
| 3.130.1.5.1.0050.1.0004 | – | 4 | 0,5 | 7,1 | 14,9 | 107 | 1000/2000 | |
| 3.130.1.5.1.0050.1.0005 | – | 5 | 0,5 | 7,2 | 18,6 | 112 | 1000/2000 | |
| 3.130.1.5.1.0050.1.0006 | – | 6 | 0,5 | 8,1 | 22,3 | 121 | 1000/2000 | |
| 3.130.1.5.1.0050.1.0010 | – | 10 | 0,5 | 8,7 | 37,1 | 156 | 1000/2000 | |
| 3.130.1.5.1.0050.1.0020 | – | 20 | 0,5 | 10,7 | 74,1 | 233 | 1200 | |
| 3.130.1.5.1.0050.1.0025 | – | 25 | 0,5 | 12 | 92,6 | 259 | 1200 | |
| 3.130.1.5.1.0050.1.0030 | – | 30 | 0,5 | 13,2 | 111,1 | 289 | 1200 | |
| 3.130.1.5.1.0050.1.0040 | – | 40 | 0,5 | 14,3 | 148,1 | 364 | 1200 | |
| 3.130.1.5.1.0050.1.0050 | – | 50 | 0,5 | 15,4 | 185,2 | 414 | 1200 | |
| 3.130.1.5.1.0050.1.0070 | – | 70 | 0,5 | 17,1 | 259,2 | 509 | 1200 | |
| 3.130.1.5.1.0050.1.0080 | – | 80 | 0,5 | 18,1 | 296,2 | 557 | 1200 | |
| 3.130.1.5.1.0050.1.0100 | – | 100 | 0,5 | 20,1 | 377,5 | 691 | 1000 | |
| 3.130.1.5.1.0050.1.0150 | – | 150 | 0,5 | 24,7 | 566,2 | 1005 | 1000 | |
| 3.130.1.5.1.0050.1.0200 | – | 200 | 0,5 | 27,3 | 755 | 1244 | 1000 | |
| KPD-AP-A (Pair) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.1.5.1.0060.1.0002 | – | 2 | 0,6 | 6,8 | 10,7 | 102 | 1000/2000 | |
| 3.130.1.5.1.0060.1.0004 | – | 4 | 0,6 | 8,1 | 21,4 | 121 | 1000/2000 | |
| 3.130.1.5.1.0060.1.0005 | – | 5 | 0,6 | 8,3 | 26,7 | 142 | 1000/2000 | |
| 3.130.1.5.1.0060.1.0006 | – | 6 | 0,6 | 9,4 | 32 | 153 | 1000/2000 | |
| 3.130.1.5.1.0060.1.0010 | – | 10 | 0,6 | 10,2 | 53,4 | 185 | 1200 | |
| 3.130.1.5.1.0060.1.0020 | – | 20 | 0,6 | 12,9 | 106,7 | 288 | 1200 | |
| 3.130.1.5.1.0060.1.0025 | – | 25 | 0,6 | 14,6 | 133,3 | 329 | 1200 | |
| 3.130.1.5.1.0060.1.0030 | – | 30 | 0,6 | 16,3 | 160 | 398 | 1200 | |
| 3.130.1.5.1.0060.1.0040 | – | 40 | 0,6 | 17,7 | 213,3 | 498 | 1200 | |
| 3.130.1.5.1.0060.1.0050 | – | 50 | 0,6 | 19,3 | 266,6 | 572 | 1200 | |
| 3.130.1.5.1.0060.1.0070 | – | 70 | 0,6 | 21,5 | 373,2 | 714 | 1000 | |
| 3.130.1.5.1.0060.1.0080 | – | 80 | 0,6 | 22,8 | 426,6 | 784 | 1000 | |
| 3.130.1.5.1.0060.1.0100 | – | 100 | 0,6 | 26 | 543,6 | 1023 | 1000 | |
| 3.130.1.5.1.0060.1.0150 | – | 150 | 0,6 | 32,1 | 815,4 | 1396 | 500 | |
| 3.130.1.5.1.0060.1.0200 | – | 200 | 0,6 | 35,6 | 1087,1 | 1823 | 500 | |
| KPD-AP-A (Pair) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.1.5.1.0063.1.0002 | – | 2 | 0,63 | 6,9 | 11,8 | 104 | 1000/2000 | |
| 3.130.1.5.1.0063.1.0004 | – | 4 | 0,63 | 8,3 | 23,6 | 126 | 1000/2000 | |
| 3.130.1.5.1.0063.1.0005 | – | 5 | 0,63 | 8,4 | 29,4 | 144 | 1000/2000 | |
| 3.130.1.5.1.0063.1.0006 | – | 6 | 0,63 | 9,7 | 35,3 | 158 | 1000/2000 | |
| 3.130.1.5.1.0063.1.0010 | – | 10 | 0,63 | 10,4 | 58,8 | 195 | 1200 | |
| 3.130.1.5.1.0063.1.0020 | – | 20 | 0,63 | 13,3 | 117,6 | 304 | 1200 | |
| 3.130.1.5.1.0063.1.0025 | – | 25 | 0,63 | 15,1 | 147 | 348 | 1200 | |
| 3.130.1.5.1.0063.1.0030 | – | 30 | 0,63 | 16,8 | 176,4 | 420 | 1200 | |
| 3.130.1.5.1.0063.1.0040 | – | 40 | 0,63 | 18,3 | 235,2 | 527 | 1200 | |
| 3.130.1.5.1.0063.1.0050 | – | 50 | 0,63 | 19,9 | 293,9 | 609 | 1200 | |
| 3.130.1.5.1.0063.1.0070 | – | 70 | 0,63 | 22,4 | 411,5 | 768 | 1000 | |
| 3.130.1.5.1.0063.1.0080 | – | 80 | 0,63 | 23,8 | 470,3 | 848 | 1000 | |
| 3.130.1.5.1.0063.1.0100 | – | 100 | 0,63 | 26,9 | 599,3 | 1095 | 1000 | |
| 3.130.1.5.1.0063.1.0150 | – | 150 | 0,63 | 33,5 | 898,9 | 1508 | 500 | |
| 3.130.1.5.1.0063.1.0200 | – | 200 | 0,63 | 37,1 | 1198,5 | 1973 | 500 | |
| KPD-AP-A (Pair) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.1.5.1.0065.1.0002 | – | 2 | 0,65 | 7 | 12,6 | 105 | 1000/2000 | |
| 3.130.1.5.1.0065.1.0004 | – | 4 | 0,65 | 8,4 | 25,1 | 128 | 1000/2000 | |
| 3.130.1.5.1.0065.1.0005 | – | 5 | 0,65 | 8,6 | 31,3 | 148 | 1000/2000 | |
| 3.130.1.5.1.0065.1.0006 | – | 6 | 0,65 | 9,9 | 37,6 | 162 | 1000/2000 | |
| 3.130.1.5.1.0065.1.0010 | – | 10 | 0,65 | 10,7 | 62,6 | 201 | 1200 | |
| 3.130.1.5.1.0065.1.0020 | – | 20 | 0,65 | 13,6 | 125,2 | 317 | 1200 | |
| 3.130.1.5.1.0065.1.0025 | – | 25 | 0,65 | 15,5 | 156,5 | 362 | 1200 | |
| 3.130.1.5.1.0065.1.0030 | – | 30 | 0,65 | 17,3 | 187,8 | 439 | 1200 | |
| 3.130.1.5.1.0065.1.0040 | – | 40 | 0,65 | 18,9 | 250,3 | 551 | 1200 | |
| 3.130.1.5.1.0065.1.0050 | – | 50 | 0,65 | 20,6 | 312,9 | 636 | 1000 | |
| 3.130.1.5.1.0065.1.0070 | – | 70 | 0,65 | 23,1 | 438 | 805 | 1000 | |
| 3.130.1.5.1.0065.1.0080 | – | 80 | 0,65 | 24,6 | 500,6 | 889 | 1000 | |
| 3.130.1.5.1.0065.1.0100 | – | 100 | 0,65 | 27,8 | 637,9 | 1148 | 1000 | |
| 3.130.1.5.1.0065.1.0150 | – | 150 | 0,65 | 34,7 | 956,9 | 1590 | 500 | |
| 3.130.1.5.1.0065.1.0200 | – | 200 | 0,65 | 38,4 | 1275,8 | 2077 | 500 | |
| KPD-AP-A (Pair) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.1.5.1.0080.1.0002 | – | 2 | 0,8 | 7,6 | 19 | 127 | 1000/2000 | |
| 3.130.1.5.1.0080.1.0004 | – | 4 | 0,8 | 9,3 | 38 | 159 | 1000/2000 | |
| 3.130.1.5.1.0080.1.0005 | – | 5 | 0,8 | 9,5 | 47,4 | 171 | 1000/2000 | |
| 3.130.1.5.1.0080.1.0006 | – | 6 | 0,8 | 11 | 56,9 | 191 | 1200 | |
| 3.130.1.5.1.0080.1.0010 | – | 10 | 0,8 | 11,9 | 94,8 | 245 | 1200 | |
| 3.130.1.5.1.0080.1.0020 | – | 20 | 0,8 | 15,4 | 189,6 | 401 | 1200 | |
| 3.130.1.5.1.0080.1.0025 | – | 25 | 0,8 | 17,7 | 237 | 466 | 1200 | |
| 3.130.1.5.1.0080.1.0030 | – | 30 | 0,8 | 19,9 | 284,4 | 565 | 1200 | |
| 3.130.1.5.1.0080.1.0040 | – | 40 | 0,8 | 21,7 | 379,2 | 715 | 1000 | |
| 3.130.1.5.1.0080.1.0050 | – | 50 | 0,8 | 23,8 | 473,9 | 838 | 1000 | |
| 3.130.1.5.1.0080.1.0070 | – | 70 | 0,8 | 26,6 | 663,5 | 1078 | 1000 | |
| 3.130.1.5.1.0080.1.0080 | – | 80 | 0,8 | 28,4 | 758,3 | 1199 | 1000 | |
| 3.130.1.5.1.0080.1.0100 | – | 100 | 0,8 | 32,4 | 966,3 | 1549 | 500 | |
| 3.130.1.5.1.0080.1.0150 | – | 150 | 0,8 | 40,5 | 1449,5 | 2189 | 400 | |
| 3.130.1.5.1.0080.1.0200 | – | 200 | 0,8 | 45 | 1932,6 | 2869 | 400 | |
| KPD-AP-A (Pair) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
| 3.130.1.5.1.0090.1.0002 | – | 2 | 0,9 | 7,9 | 24 | 134 | 1000/2000 | |
| 3.130.1.5.1.0090.1.0004 | – | 4 | 0,9 | 9,8 | 48 | 172 | 1000/2000 | |
| 3.130.1.5.1.0090.1.0005 | – | 5 | 0,9 | 10 | 60 | 188 | 1000/2000 | |
| 3.130.1.5.1.0090.1.0006 | – | 6 | 0,9 | 11,7 | 72 | 212 | 1200 | |
| 3.130.1.5.1.0090.1.0010 | – | 10 | 0,9 | 12,7 | 120 | 299 | 1200 | |
| 3.130.1.5.1.0090.1.0020 | – | 20 | 0,9 | 16,5 | 240 | 487 | 1200 | |
| 3.130.1.5.1.0090.1.0025 | – | 25 | 0,9 | 19 | 299,9 | 569 | 1200 | |
| 3.130.1.5.1.0090.1.0030 | – | 30 | 0,9 | 21,4 | 359,9 | 683 | 1000 | |
| 3.130.1.5.1.0090.1.0040 | – | 40 | 0,9 | 23,4 | 479,9 | 904 | 1000 | |
| 3.130.1.5.1.0090.1.0050 | – | 50 | 0,9 | 26,1 | 599,8 | 1071 | 1000 | |
| 3.130.1.5.1.0090.1.0070 | – | 70 | 0,9 | 29 | 839,7 | 1360 | 1000 | |
| 3.130.1.5.1.0090.1.0080 | – | 80 | 0,9 | 31 | 959,7 | 1510 | 500 | |
| 3.130.1.5.1.0090.1.0100 | – | 100 | 0,9 | 35,7 | 1223 | 1955 | 500 | |
| 3.130.1.5.1.0090.1.0150 | – | 150 | 0,9 | 44,1 | 1834,5 | 2639 | 400 | |
| 3.130.1.5.1.0090.1.0200 | – | 200 | 0,9 | 48,7 | 2446 | 3376 | 400 | |