Product Categories

A-02YSF(L)2YB2Y Outdoor Telephone Cable

Product Code:

  • Cable Construction
  • Technical Data
  • Types
1 – Conductor : Electrolytic annealed solid copper (CCITT Yellow Book Vol. III-2-G.541 B article, IEC 28 and ASTM B 3).
2 – Insulation : Color coded foam skin polyethylene cladded with solid polyethylene (BS 6234 Type 03 – ASTM D 1248).
3 – Stranding : Star quads or pairs are assembled into 10 pairs units. Groups having 25, 50 or 100 pairs are stranded together.
4 – Filling Compound : Cable core is filled with a special jelly filling compound to avoid the water leakage into air spaces.
5 – Wrapping : A non-hygroscopic and dielectric polyester tape is applied on the cable core longitudinally or helically.
6 – Filling Compound : Secondary jelly filling is applied between wrapping and screen in order to provide waterproofness.
7 – Screen : Both sides are coated with copolymer coated flat aluminum tape over cable core longitudinally for screening.
8 – Inner Jacket : Linear low-density or medium-density, UV resistant black polyethylene inner jacket (ASTM D 1248).
9 – Filling Compound : A filling compund (Jelly) is applied between inner jacket and armor in order to have waterproofness.
10 – Armor : Copolymer coated corrugated steel tape is applied to secure the cable from rodents.
11 – Outer Jacket : Linear low-density or medium-density, UV resistant black polyethylene outer jacket (ASTM D 1248).
Conductor Diameter
0.40 mm 0.50 mm 0.60 mm 0.63 mm 0.65 mm 0.80 mm 0.90 mm
Conductor Resistance Ω/km (20 °C)
Maximum Average 139,4 89,4 62,1 58 57 35 27,6
Maximum Individual 146,6 93 64,6 60 58 37 28,8
Insulation Resistance MΩ/km (500 VDC) >10000 >10000 >15000 >15000 >15000 >15000 >15000
Mutual Capacitance nF/km (800 Hz)
Maximum Average 50 50 45 45 45 45 45
Maximum Individual 56 56 51 51 51 51 51
Capacitance Unbalance pF/500 m
Between Pairs
Maximum Average 125 125 60 60 60 60 60
Maximum Individual 350 350 325 325 325 325 325
Between Adjacent Quads
Maximum Average 125 125 60 60 60 60 60
Maximum Individual 275 275 270 270 270 270 270
To Screen
Maximum Average 500 500 325 325 325 325 325
Maximum Individual 2000 2000 1300 1300 1300 1300 1300
Dielectric Strength
V (DC, 1 minute)
Pair – Pair 1400 1400 2000 2000 2000 2400 3000
Pair – Screen 1400 1400 2000 2000 2000 2400 3000
V (DC, 3 second)
Pair – Screen 9000 9000 9000 9000 9000 9000 9000
KPDF-PABP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.175.1.5.1.0040.1.0002 2 0,4 10 4,8 146 1000/2000
3.175.1.5.1.0040.1.0004 4 0,4 10,9 9,5 155 1200
3.175.1.5.1.0040.1.0006 6 0,4 11,7 14,3 172 1200
3.175.1.5.1.0040.1.0010 10 0,4 12 23,7 185 1200
3.175.1.5.1.0040.1.0020 20 0,4 14,6 47,4 268 1200
3.175.1.5.1.0040.1.0025 25 0,4 15,7 59,3 301 1200
3.175.1.5.1.0040.1.0030 30 0,4 16,8 71,1 349 1200
3.175.1.5.1.0040.1.0040 40 0,4 17,7 94,8 398 1200
3.175.1.5.1.0040.1.0050 50 0,4 18,7 118,5 444 1200
3.175.1.5.1.0040.1.0070 70 0,4 20,2 165,9 539 1000
3.175.1.5.1.0040.1.0080 80 0,4 21,1 189,6 586 1000
3.175.1.5.1.0040.1.0100 100 0,4 22,9 241,6 701 1000
3.175.1.5.1.0040.1.0150 150 0,4 27 362,4 965 1000
3.175.1.5.1.0040.1.0200 200 0,4 29,3 483,2 1190 1000
3.175.1.5.1.0040.1.0250 250 0,4 31,9 604 1397 500
3.175.1.5.1.0040.1.0300 300 0,4 34,1 724,8 1611 500
KPDF-PABP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.175.1.5.1.0050.1.0002 2 0,5 10,8 7,5 145 1200
3.175.1.5.1.0050.1.0004 4 0,5 11,9 14,9 177 1200
3.175.1.5.1.0050.1.0006 6 0,5 12,9 22,3 208 1200
3.175.1.5.1.0050.1.0010 10 0,5 13,2 37,1 227 1200
3.175.1.5.1.0050.1.0020 20 0,5 15,6 74,1 316 1200
3.175.1.5.1.0050.1.0025 25 0,5 17 92,6 366 1200
3.175.1.5.1.0050.1.0030 30 0,5 18,5 111,1 437 1200
3.175.1.5.1.0050.1.0040 40 0,5 19,6 148,1 506 1200
3.175.1.5.1.0050.1.0050 50 0,5 20,9 185,2 574 1000
3.175.1.5.1.0050.1.0070 70 0,5 22,7 259,2 709 1000
3.175.1.5.1.0050.1.0080 80 0,5 23,8 296,2 776 1000
3.175.1.5.1.0050.1.0100 100 0,5 26,2 377,5 947 1000
3.175.1.5.1.0050.1.0150 150 0,5 31,1 566,2 1336 500
3.175.1.5.1.0050.1.0200 200 0,5 34 755 1638 500
3.175.1.5.1.0050.1.0250 250 0,5 36,9 943,7 1886 500
3.175.1.5.1.0050.1.0300 300 0,5 40 1132,4 2313 500
KPDF-PABP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.175.1.5.1.0060.1.0002 2 0,6 10,3 10,7 138 1200
3.175.1.5.1.0060.1.0004 4 0,6 11,6 21,4 176 1200
3.175.1.5.1.0060.1.0006 6 0,6 13,8 32 241 1200
3.175.1.5.1.0060.1.0010 10 0,6 14,2 53,4 266 1200
3.175.1.5.1.0060.1.0020 20 0,6 17,8 106,7 409 1200
3.175.1.5.1.0060.1.0025 25 0,6 19,2 133,3 473 1200
3.175.1.5.1.0060.1.0030 30 0,6 21,4 160 570 1000
3.175.1.5.1.0060.1.0040 40 0,6 22,8 213,3 670 1000
3.175.1.5.1.0060.1.0050 50 0,6 24,5 266,6 778 1000
3.175.1.5.1.0060.1.0070 70 0,6 26,8 373,2 968 1000
3.175.1.5.1.0060.1.0080 80 0,6 28,2 426,6 1069 1000
3.175.1.5.1.0060.1.0100 100 0,6 31,1 543,6 1300 500
3.175.1.5.1.0060.1.0150 150 0,6 37,7 815,4 1891 500
3.175.1.5.1.0060.1.0200 200 0,6 41,3 1087,1 2335 400
KPDF-PABP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.175.1.5.1.0063.1.0002 2 0,63 10,5 11,8 144 1200
3.175.1.5.1.0063.1.0004 4 0,63 11,9 23,6 193 1200
3.175.1.5.1.0063.1.0006 6 0,63 14,3 35,3 252 1200
3.175.1.5.1.0063.1.0010 10 0,63 14,7 58,8 282 1200
3.175.1.5.1.0063.1.0020 20 0,63 18,5 117,6 437 1200
3.175.1.5.1.0063.1.0025 25 0,63 20,1 147 507 1000
3.175.1.5.1.0063.1.0030 30 0,63 22,4 176,4 624 1000
3.175.1.5.1.0063.1.0040 40 0,63 24 235,2 732 1000
3.175.1.5.1.0063.1.0050 50 0,63 25,8 293,9 853 1000
3.175.1.5.1.0063.1.0070 70 0,63 28,3 411,5 1062 1000
3.175.1.5.1.0063.1.0080 80 0,63 29,8 470,3 1175 1000
3.175.1.5.1.0063.1.0100 100 0,63 32,9 599,3 1444 500
3.175.1.5.1.0063.1.0150 150 0,63 40,1 898,9 2093 400
3.175.1.5.1.0063.1.0200 200 0,63 43,9 1198,5 2587 400
KPDF-PABP (Pair)
Part Number Number of Conductors Pair Count Conductor Diameter (mm) Approx. Cable Diameter (mm) Copper Weight (kg/km) Approx. Weight (kg/km) Packing Lengths (m)
3.175.1.5.1.0080.1.0002 2 0,8 11,2 19 168 1200
3.175.1.5.1.0080.1.0004 4 0,8 13 38 231 1200
3.175.1.5.1.0080.1.0006 6 0,8 15,6 56,9 301 1200
3.175.1.5.1.0080.1.0010 10 0,8 16,2 94,8 352 1200
3.175.1.5.1.0080.1.0020 20 0,8 20,7 189,6 568 1000
3.175.1.5.1.0080.1.0025 25 0,8 22,5 237 664 1000
3.175.1.5.1.0080.1.0030 30 0,8 25,4 284,4 818 1000
3.175.1.5.1.0080.1.0040 40 0,8 27,4 379,2 993 1000
3.175.1.5.1.0080.1.0050 50 0,8 29,6 473,9 1171 1000
3.175.1.5.1.0080.1.0070 70 0,8 32,7 663,5 1482 500
3.175.1.5.1.0080.1.0080 80 0,8 34,6 758,3 1653 500
3.175.1.5.1.0080.1.0100 100 0,8 38,4 966,3 2046 500