Product Categories

J-V(ZN)H Fiber Optic Cable

Product Code: TB-NMA-SHFJ

  • Cable Construction
  • Types
  • Mechanical and Environmental Characteristics
  • Application
  • Marking, Packing, Delivery Lengths

1 – Optical fiber core ¹
2 – HFFR insulated tight-buffered fiber of 900 μm diameter
3 – Non-metallic strength member (Glass yarn or aramid yarn)
4 – Ripcord
5 – UV resistant halogen-free (LSOH) outer jacket

Part Number Core Type Fiber Count Cable Diameter (mm) Cable Weight (kg/km)
4.294.0.3.1.0900.0.0002 SM G.652.D 2 4,6 22
4.294.0.3.1.0900.0.0004 SM G.652.D 4 5,1 27
4.294.0.3.1.0900.0.0006 SM G.652.D 6 5,7 32
4.294.0.3.1.0900.0.0008 SM G.652.D 8 6,6 42
4.294.0.3.1.0900.0.0012 SM G.652.D 12 7,2 50
4.294.0.3.1.0900.0.0024 SM G.652.D 24 9,1 76
Part Number Core Type Fiber Count Cable Diameter (mm) Cable Weight (kg/km)
4.294.0.3.1.0625.0.0002 OM1 2 4,6 22
4.294.0.3.1.0625.0.0004 OM1 4 5,1 27
4.294.0.3.1.0625.0.0006 OM1 6 5,7 32
4.294.0.3.1.0625.0.0008 OM1 8 6,6 42
4.294.0.3.1.0625.0.0012 OM1 12 7,2 50
4.294.0.3.1.0625.0.0024 OM1 24 9,1 76
Part Number Core Type Fiber Count Cable Diameter (mm) Cable Weight (kg/km)
4.294.0.3.1.0502.0.0002 OM2 2 4,6 22
4.294.0.3.1.0502.0.0004 OM2 4 5,1 27
4.294.0.3.1.0502.0.0006 OM2 6 5,7 32
4.294.0.3.1.0502.0.0008 OM2 8 6,6 42
4.294.0.3.1.0502.0.0012 OM2 12 7,2 50
4.294.0.3.1.0502.0.0024 OM2 24 9,1 76
Part Number Core Type Fiber Count Cable Diameter (mm) Cable Weight (kg/km)
4.294.0.3.1.0503.0.0002 OM3 2 4,6 22
4.294.0.3.1.0503.0.0004 OM3 4 5,1 27
4.294.0.3.1.0503.0.0006 OM3 6 5,7 32
4.294.0.3.1.0503.0.0008 OM3 8 6,6 42
4.294.0.3.1.0503.0.0012 OM3 12 7,2 50
4.294.0.3.1.0503.0.0024 OM3 24 9,1 76
Test Standard Specified Value Acceptance Criteria
Maximum Installation Tension ² IEC 60794-1-2-E1 1.0 x W(N), min. 1000 N Fiber strainı ≤ 0.33%
Maximum Operation Tension IEC 60794-1-2-E1 0.5 x W(N), min. 500 N Δα ≤ 0.05 dB, No fiber strain
Crush Strength IEC 60794-1-2-E3 1000 N / 100 mm, maks. 10 min Δα ≤ 0.05 dB, No damage
Impact IEC 60794-1-2-E4 10 Nm, 3 impacts, R= 300 mm Δα ≤ 0.05 dB after the test
Torsion IEC 60794-1-2-E7 1 m, 100N, +/- 180°, 10 cycles Δα ≤ 0.05 dB, No damage
Repeated Bending IEC 60794-1-2-E6 R=20x D, 100 N, 35 cycles No damage
Bending Radius IEC 60794-1-2-E11 R=20x D, 4 turns, 3 cycles Δα ≤ 0.05 dB, No damage
Temperature Cycling IEC 60794-1-2-F1 -20°C to +70°C Δα ≤ 0.05 dB/km
Minimum Bending Radius
Operation 20 x cable Ø
Fixed 15 x cable Ø
Temperature Range
Storage -40°C to + 70°C Installation -30°C to +60°C
Transport -40°C to + 70°C Operating -40°C to +70°C
Marking Camcom – Signaling Innovation – Date of Manufacture – Fiber Count and Type – Length Marking
Packing Wooden drum with protection
Delivery Lengths 2 km, 4 km ± %5 tolerance