Intercom Cable (DT)
Product Code: Intercom Cable (DT)
| 1 – Conductor | : | Stranded copper conductor |
| 2 – Insulation | : | PVC (TS IEC 60189-2, EN 50290-2-21) (DIN 47100), halogen-free (TS IEC 60189-2, EN 50290-2-26) (DIN 47100) |
| 3 – Wrapping | : | Polyester tape |
| 4 – Outer Jacket | : | UV resistant PVC outer jacket RAL 9001 (White), UV resistant halogen-free outer jacket RAL 7035 (Grey) |
| Inner Conductor Resistance (20°C) |
Insulation Resistance MΩxkm |
Operating Voltage V |
Test Voltage V |
|---|---|---|---|
| <92.0 km=”” –92=”” 0–=””> | >200 | 300/500 | 1200 |
| Smoke Density Test | Corrosive Gas Test | Halogen-free Test | Flame Retardancy Test |
|---|---|---|---|
| IEC 61034-2 VDE 0482-1034-2 EN 61034-2 |
IEC 60754-2 VDE 0482-267-2-3 EN 50267-2-3 |
IEC 60754-1 VDE 0482-267-2-1 EN 50267-2-1 |
IEC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2 |
| PartNumber | Conductor Count | Conductor Diameter(mm²) | Approx. Cable Diameter(mm) | Copper Weight(kg/km) | Approx. Weight(kg/km) | Packing Lengths(m) |
|---|---|---|---|---|---|---|
| 3.620.2.2.2.0014.0.0004 | 4 | 0.14 | 3,8 | 5,5 | 19 | 100 |
| 3.620.2.2.2.0014.0.0006 | 6 | 0.14 | 4,6 | 8,2 | 29 | 100 |
| 3.620.2.2.2.0014.0.0008 | 8 | 0.14 | 5,2 | 11 | 37 | 100 |
| 3.620.2.2.2.0014.0.0012 | 12 | 0.14 | 6,2 | 16,4 | 51 | 100 |
| 3.620.2.2.2.0014.0.0016 | 16 | 0.14 | 6,9 | 21,9 | 65 | 100 |
| 3.620.2.2.2.0014.0.0020 | 20 | 0.14 | 7,7 | 27,4 | 79 | 100 |
| PartNumber | Conductor Count | Conductor Diameter(mm²) | Approx. Cable Diameter(mm) | Copper Weight(kg/km) | Approx. Weight(kg/km) | Packing Lengths(m) |
|---|---|---|---|---|---|---|
| 3.620.2.2.2.0022.0.0004 | 4 | 0.22 | 4 | 8,6 | 23 | 100 |
| 3.620.2.2.2.0022.0.0006 | 6 | 0.22 | 4,9 | 12,9 | 35 | 100 |
| 3.620.2.2.2.0022.0.0008 | 8 | 0.22 | 5,5 | 17,1 | 46 | 100 |
| 3.620.2.2.2.0022.0.0012 | 12 | 0.22 | 6,6 | 25,7 | 63 | 100 |
| 3.620.2.2.2.0022.0.0016 | 16 | 0.22 | 7,4 | 34,2 | 80 | 100 |
| 3.620.2.2.2.0022.0.0020 | 20 | 0.22 | 8,2 | 42,7 | 98 | 100 |
| PartNumber | Conductor Count | Conductor Diameter(mm²) | Approx. Cable Diameter(mm) | Copper Weight(kg/km) | Approx. Weight(kg/km) | Packing Lengths(m) |
|---|---|---|---|---|---|---|
| 3.620.2.3.2.0014.0.0004 | 4 | 0.14 | 3,8 | 5,5 | 18 | 100 |
| 3.620.2.3.2.0014.0.0006 | 6 | 0.14 | 4,6 | 8,2 | 28 | 100 |
| 3.620.2.3.2.0014.0.0008 | 8 | 0.14 | 5,2 | 11 | 36 | 100 |
| 3.620.2.3.2.0014.0.0012 | 12 | 0.14 | 6,2 | 16,4 | 49 | 100 |
| 3.620.2.3.2.0014.0.0016 | 16 | 0.14 | 6,9 | 21,9 | 62 | 100 |
| 3.620.2.3.2.0014.0.0020 | 20 | 0.14 | 7,7 | 27,4 | 77 | 100 |
| PartNumber | Conductor Count | Conductor Diameter(mm²) | Approx. Cable Diameter(mm) | Copper Weight(kg/km) | Approx. Weight(kg/km) | Packing Lengths(m) |
|---|---|---|---|---|---|---|
| 3.620.2.3.2.0022.0.0004 | 4 | 0.22 | 4 | 8,6 | 22 | 100 |
| 3.620.2.3.2.0022.0.0006 | 6 | 0.22 | 4,9 | 12,9 | 34 | 100 |
| 3.620.2.3.2.0022.0.0008 | 8 | 0.22 | 5,5 | 17,1 | 44 | 100 |
| 3.620.2.3.2.0022.0.0012 | 12 | 0.22 | 6,6 | 25,7 | 60 | 100 |
| 3.620.2.3.2.0022.0.0016 | 16 | 0.22 | 7,4 | 34,2 | 77 | 100 |
| 3.620.2.3.2.0022.0.0020 | 20 | 0.22 | 8,2 | 42,7 | 96 | 100 |
| Bending Radius | Temperature Range Operating |
|---|---|
| 10xD mm | -30°C~+70°C |