Coaxial cable
RG-58C/U
Available as 1 part number. Full construction and technical data are in the datasheet.
Conductor size
Camcom part no.
125803BS
19 x 0.18 mm · 1,000 m
Stock and lead time: ask us by email.
Construction
Four layers, from copper out.

- 1
Conductor
19×0.18 mm Ø stranded tinned copper conductor
- 2
Insulation
2.95 mm Ø solid polyethylene
- 3
Screen
Tinned copper braiding
- 4
Outer jacket
UV resistant PVC, halogen-free, polyethylene outer jacket
Technical data
The numbers behind it.
Electrical · 19 x 0.18 mm
- Insulation resistance
- >2000
- Mutual capacitance
- 101±2
- Propagation velocity
- 0,66
- Operating voltage
- 2.5
- Test voltage
- 5
- Characteristic impedance
- 50±3
Values for this size are in its datasheet.
Mechanical
- Bending radius
- 15xD mm
- Temperature range operating
- -40°C~+70°C
Standards
Manufacturing Std.
MIL-C-17
Smoke density test
IEC 61034-2 VDE 0482-1034-2 EN 61034-2
Corrosive gas test
IEC 60754-2 VDE 0482-267-2-3 EN 50267-2-3
Halogen-free test
IEC 60754-1 VDE 0482-267-2-1 EN 50267-2-1
Flame retardancy test
IEC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2
From the Camcom datasheet. The datasheet for the chosen part number is the reference.