Coaxial cable
RG-6/U-4 Trishield
Available as 1 part number. Full construction and technical data are in the datasheet.
Conductor size
Camcom part no.
120604TS
1 x 1 mm · 1,000 m
Stock and lead time: ask us by email.
Technical data
The numbers behind it.
Electrical · 1 x 1 mm
- Inner conductor resistance (20°C)
- <22.1
- Outer conductor resistance (20°C)
- <17.6
- Insulation resistance
- >2000
- Mutual capacitance
- 53±2
- Propagation velocity
- 0,84
- Operating voltage
- 1.3
- Test voltage
- 3
- Characteristic impedance
- 75±3
Values for this size are in its datasheet.
Mechanical
- Bending radius
- 15xD mm
- Temperature range operating
- -40°C~+70°C
Standards
Smoke density test
IEC 61034-2 VDE 0482-1034-2 EN 61034-2
Corrosive gas test
IEC 60754-2 VDE 0482-267-2-3 EN 50267-2-3
Halogen-free test
IEC 60754-1 VDE 0482-267-2-1 EN 50267-2-1
Flame retardancy test
IEC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2
Construction
- Conductor: 1.0 mm Ø electrolytic solid copper conductor
- Insulation: 4.60 mm Ø physical foam polyethylene
- Screen: Al/PET tape : Insulations are stranded into pairs
- 2nd screen: Aluminum braiding : Pairs are stranded together with star shaped separator
- Outer jacket: UV resistant PVC, : UV resistant halogen-free
- halogen-free, polyethylene outer jacket outer jacket
From the Camcom datasheet. The datasheet for the chosen part number is the reference.