Control cable
YSLYQY-JZ
Available as 9 part numbers from 0.50 mm² to 16.00 mm². Full construction and technical data are in the datasheet.
Conductor size
Camcom part no.
220500UNB
0.50 mm² · 1,000 m
Stock and lead time: ask us by email.
Construction
Six layers, from copper out.

- 1
Conductor
Stranded electrolytic annealed copper conductor (Class 5) (IEC 60228, EN 60228, DIN VDE 0295)
- 2
Insulation
PVC (DIN VDE 0207, EN 50363-3, TS EN 50290-2-21 TI2), Black insulation, white number coded and a Y/G insulation (DIN VDE 0293, TS EN 50334)
- 3
Stranding
In layers
- 4
Inner jacket
UV resistant PVC inner jacket (EN 50363-4-1, DIN VDE 207 TM2). RAL 7001 (Grey)
- 5
Armor
Galvanized steel wire braiding
- 6
Outer jacket
UV resistant PVC outer jacket (EN 50363-4-1, DIN VDE 207 TM2). RAL 7001 (Grey) or Transparent
Technical data
The numbers behind it.
Electrical · 0.50 mm²
- Cross section
- 0.50 mm²
- Conductor resistance (20 °C)
- 39.0 Ω/km
- Insulation resistance (@500V DC)
- 20 MΩ/km
- Operating voltage
- 300/500 V DC
- Test voltage (@ 1 minute)
- 2000 V DC
Values for this size are in its datasheet.
Mechanical
- Bending radius
- 7.5xD mm
- Temperature range operating
- -30°C ~ +70°C
Standards
Flame retardancy test
IEC 60332-1-2, VDE 0482-332-1-2, BS EN 60332-1-2
From the Camcom datasheet. The datasheet for the chosen part number is the reference.