Fibre optic cable
A-DF(ZN)2Y2BT2Y
Aerial Fiber Optic Cable, available as 6 part numbers from 4F SM G.652.D to 48F SM G.652.D. Full construction and technical data are in the datasheet.
Conductor size
Camcom part no.
826004EAA
4F SM G.652.D · 1,000 m
Stock and lead time: ask us by email.
Construction
15 layers, from the core out.

- 1
Optical fiber core
- 2
Waterproof thixotropic jelly
- 3
PBT Tube
- 4
Non-metallic central strength member (FRP)
- 5
Jelly filling
- 6
Core Wrapping (Polyester Tape)
- 7
Non-metallic strength member (Aramid yarn)
- 8
Ripcord
- 9
Polyethylene black inner jacket
- 10
Water-swellable tape
- 11
Two ballistic proof, helically laid galvanized steel tape
- 12
Ripcord
- 13
Web
- 14
Steel messenger wire (7×1.75 mm)
- 15
UV resistant polyethylene (LLDPE) black outer jacket
Technical data
The numbers behind it.
Mechanical
- Minimum bending radius – operation
- 20 x cable Ø
- Minimum bending radius – fixed
- 15 x cable Ø
- Temperature range – storage
- -40°C to + 70°C
- Temperature range – installation
- -30°C to +60°C
- Temperature range – transport
- -40°C to + 70°C
- Temperature range – operating
- -20°C to +70°C
Marking, Packing & Delivery
- Marking
- CAMCOM – Date of Manufacture – Fiber Count and Type – Length Marking
- Packing
- Wooden drum with protection
- Delivery lengths
- 2 km, 4 km ± 5 % tolerance
Mechanical & Environmental Characteristics
| Test Standard | Specified Value | Acceptance Criteria | |
|---|---|---|---|
| Maximum Installation Tension ² | IEC 60794-1-2-E1 | 3.0 x W(N), min. 5000 N | Fiber strain ≤ 0.33% |
| Maximum Operation Tension | IEC 60794-1-2-E1 | 1.0 x W(N), min. 1500 N | Δα ≤ 0.05 dB, No fiber strain |
| Crush Strength | IEC 60794-1-2-E3 | 5000 N / 100 mm, maks. 15 min | Δα ≤ 0.05 dB, No damage |
| Impact | IEC 60794-1-2-E4 | 10 Nm, 3 impacts, R= 300 mm | Δα ≤ 0.05 dB after the test |
| Torsion | IEC 60794-1-2-E7 | 1 m, 100N, +/- 180°, 10 cycles | Δα ≤ 0.05 dB, No damage |
| Repeated Bending | IEC 60794-1-2-E6 | R=20x D, 100 N, 35 cycles | No damage |
| Bending Radius | IEC 60794-1-2-E11 | R=20x D, 4 turns, 3 cycles | Δα ≤ 0.05 dB, No damage |
| Temperature Cycling | IEC 60794-1-2-F1 | -20°C to +70°C | Δα ≤ 0.05 dB/km |
| Waterproofness | IEC 60794-1-2-F5B | Sample= 3 m, water column= 1 m | No water leakage in 24 hours. |
From the Camcom datasheet. The datasheet for the chosen part number is the reference.