A-DQ2Y(ZN)2Y cable, stripped back to show its construction

Fibre optic cable

A-DQ2Y(ZN)2Y

Indoor/Outdoor Fiber Optic Cable, available as 60 part numbers from 2F SM G.652.D to 216F SM G.652.D. Full construction and technical data are in the datasheet.

Non-Metallic Armored Fiber Optic Cable

Conductor size

Camcom part no.

886002EBA

2F SM G.652.D · 1,000 m

Request a quote

Stock and lead time: ask us by email.

Construction

Eleven layers, from the core out.

Cross-section of A-DQ2Y(ZN)2Y
  1. 1

    Optical fiber core ¹

  2. 2

    Waterproof thixotropic jelly

  3. 3

    PBT Tube

  4. 4

    Non-metallic central strength member (FRP)

  5. 5

    Water-swellable yarn

  6. 6

    Core Wrapping (Water-swellable Tape)

  7. 7

    Ripcord

  8. 8

    UV resistant polyethylene (LLDPE) black inner jacket.

  9. 9

    Non-metallic strength member (Aramid yarn)

  10. 10

    Ripcord

  11. 11

    UV resistant polyethylene (HDPE) black outer jacket

Technical data

The numbers behind it.

Mechanical

Minimum bending radius – operation
20 x cable Ø
Minimum bending radius – fixed
15 x cable Ø
Temperature range – storage
-40°C to + 70°C
Temperature range – installation
-30°C to +60°C
Temperature range – transport
-40°C to + 70°C
Temperature range – operating
-20°C to +70°C

Marking, Packing & Delivery

Marking
CAMCOM – Date of Manufacture – Fiber Count and Type – Length Marking
Packing
Wooden drum with protection
Delivery lengths
2 km, 4 km ± 5 % tolerance

Mechanical & Environmental Characteristics

Test StandardSpecified ValueAcceptance Criteria
Maximum Installation Tension ²IEC 60794-1-2-E11.5 x W(N), min. 2700 NFiber strain ≤ 0.33%
Maximum Operation TensionIEC 60794-1-2-E10.5 x W(N), min. 900 NΔα ≤ 0.05 dB, No fiber strain
Crush StrengthIEC 60794-1-2-E34000 N / 100 mm, max. 15 min.Δα ≤ 0.05 dB, No damage
ImpactIEC 60794-1-2-E410 Nm, 3 impacts, R= 300 mmΔα ≤ 0.05 dB after the test
TorsionIEC 60794-1-2-E71 m. 100N, +/- 180°, 10 cyclesΔα ≤ 0.05 dB, No damage
Repeated BendingIEC 60794-1-2-E6R=20x D, 100 N, 35 cyclesNo damage
Bending RadiusIEC 60794-1-2-E11R=20x D, 4 turns, 3 cyclesΔα ≤ 0.05 dB, No damage
Temperature CyclingIEC 60794-1-2-F1-20°C to +70°CΔα ≤ 0.05 dB/km
WaterproofnessIEC 60794-1-2-F5BSample= 3 m, water column= 1 mNo water leakage in 24 hours.

From the Camcom datasheet. The datasheet for the chosen part number is the reference.

Cable type data

Every size, one part number each.

Camcom part no.Conductor sizeDatasheet
886002EBA2F SM G.652.DPDF ↓
886004EBB4F SM G.652.DPDF ↓
886004EBA4F SM G.652.DPDF ↓
886006EBB6F SM G.652.DPDF ↓
886006EBA6F SM G.652.DPDF ↓
886008EBB8F SM G.652.DPDF ↓
886008EBC8F SM G.652.DPDF ↓
886008EBA8F SM G.652.DPDF ↓
886012EBB12F SM G.652.DPDF ↓
886012EBC12F SM G.652.DPDF ↓
886012EBA12F SM G.652.DPDF ↓
886016EBB16F SM G.652.DPDF ↓
886016EBA16F SM G.652.DPDF ↓
886020EBA20F SM G.652.DPDF ↓
886024EBB24F SM G.652.DPDF ↓
886024EBD24F SM G.652.DPDF ↓
886024EBC24F SM G.652.DPDF ↓
886024EBA24F SM G.652.DPDF ↓
886032EBA32F SM G.652.DPDF ↓
886036EBA36F SM G.652.DPDF ↓