A-V(ZN)H(SR)T2Y cable, stripped back to show its construction

Fibre optic cable

A-V(ZN)H(SR)T2Y

Indoor Fiber Optic Cable, available as 20 part numbers from 2F SM G.652.D to 12F OM3. Full construction and technical data are in the datasheet.

Indoor Fiber Optic Cable

Conductor size

Camcom part no.

866002BAA

2F SM G.652.D · 1,000 m

Request a quote

Stock and lead time: ask us by email.

Construction

Ten layers, from the core out.

Cross-section of A-V(ZN)H(SR)T2Y
  1. 1

    Optical fiber core

  2. 2

    HFFR insulated tight-buffered fiber of

  3. 3

    900 μm diameter

  4. 4

    Non-metallic strength member (Glass yarn or aramid yarn)

  5. 5

    UV resistant halogen-free (LSOH) black inner jacket.

  6. 6

    Ripcord

  7. 7

    Corrugated steel tape

  8. 8

    Web

  9. 9

    Steel messenger wire

  10. 10

    UV resistant polyethylene black outer jacket

Technical data

The numbers behind it.

Mechanical

Minimum bending radius – operation
20 x cable Ø
Minimum bending radius – fixed
15 x cable Ø
Temperature range – storage
-40°C to + 70°C
Temperature range – installation
-30°C to +60°C
Temperature range – transport
-40°C to + 70°C
Temperature range – operating
-40°C to +70°C

Marking, Packing & Delivery

Marking
CAMCOM – Date of Manufacture – Fiber Count and Type – Length Marking
Packing
Wooden drum with protection
Delivery lengths
2 km, 4 km ± 5 % tolerance

Mechanical & Environmental Characteristics

Test StandardSpecified ValueAcceptance Criteria
Maximum Installation Tension ²IEC 60794-1-2-E11.0 x W(N), min. 1500 NFiber strain ≤ 0.33%
Maximum Operation TensionIEC 60794-1-2-E10.5 x W(N), min. 750 NΔα ≤ 0.05 dB, No fiber strain
Crush StrengthIEC 60794-1-2-E31000 N / 100 mm, maks. 10 minΔα ≤ 0.05 dB, No damage
ImpactIEC 60794-1-2-E410 Nm, 3 impacts, R= 300 mmΔα ≤ 0.05 dB after the test
TorsionIEC 60794-1-2-E71 m, 100N, +/- 180°, 10 cyclesΔα ≤ 0.05 dB, No damage
Repeated BendingIEC 60794-1-2-E6R=20x D, 100 N, 35 cyclesNo damage
Bending RadiusIEC 60794-1-2-E11R=20x D, 4 turns, 3 cyclesΔα ≤ 0.05 dB, No damage
Temperature CyclingIEC 60794-1-2-F1-20°C to +70°CΔα ≤ 0.05 dB/km

From the Camcom datasheet. The datasheet for the chosen part number is the reference.

Cable type data

Every size, one part number each.

Camcom part no.Conductor sizeDatasheet
866002BAA2F SM G.652.DPDF ↓
866004BAA4F SM G.652.DPDF ↓
866006BAA6F SM G.652.DPDF ↓
866008BAA8F SM G.652.DPDF ↓
866012BAA12F SM G.652.DPDF ↓
861002BAA2F OM1PDF ↓
861004BAA4F OM1PDF ↓
861006BAA6F OM1PDF ↓
861008BAA8F OM1PDF ↓
861012BAA12F OM1PDF ↓
862002BAA2F OM2PDF ↓
862004BAA4F OM2PDF ↓
862006BAA6F OM2PDF ↓
862008BAA8F OM2PDF ↓
862012BAA12F OM2PDF ↓
863002BAA2F OM3PDF ↓
863004BAA4F OM3PDF ↓
863006BAA6F OM3PDF ↓
863008BAA8F OM3PDF ↓
863012BAA12F OM3PDF ↓