Indoor telephone cable
Jumper Wire
Available as 3 part numbers from 2 x 2 x 0.5 mm to 2 x 2 x 0.8 mm. Full construction and technical data are in the datasheet.
Conductor size
Camcom part no.
605002UN
2 x 2 x 0.5 mm · 1,000 m
Stock and lead time: ask us by email.
Construction
Three layers, from copper out.

- 1
Conductor
Class 1 electrolytic solid copper (IEC 60228, DIN VDE 0295, EN 60228)
- 2
Insulation
UV resistant PVC insulation (BS 6746). RAL 5015 (Blue) or RAL 3000 (Red)/RAL 9001 (White)
- 3
Stranding
Insulations are stranded together.
Technical data
The numbers behind it.
Electrical · 2 x 2 x 0.5 mm
- Conductor diameter
- 0.50 mm
- Conductor resistance (20 °C)
- 93.0 Ω/km
- Insulation resistance (@500V DC)
- 500 MΩ/km
- Dielectric strength (DC. 1 minute)
- 1000 V
- Test voltage (@ 1 minute)
- 1500 V DC
Values for this size are in its datasheet.
Mechanical
- Bending radius
- 7.5xD mm
- Temperature range operating
- -30°C ~ +70°C
From the Camcom datasheet. The datasheet for the chosen part number is the reference.