Jumper Wire cable, stripped back to show its construction

Indoor telephone cable

Jumper Wire

Available as 3 part numbers from 2 x 2 x 0.5 mm to 2 x 2 x 0.8 mm. Full construction and technical data are in the datasheet.

Unshielded

Conductor size

Camcom part no.

605002UN

2 x 2 x 0.5 mm · 1,000 m

Request a quote

Stock and lead time: ask us by email.

Construction

Three layers, from copper out.

Cross-section of Jumper Wire
  1. 1

    Conductor

    Class 1 electrolytic solid copper (IEC 60228, DIN VDE 0295, EN 60228)

  2. 2

    Insulation

    UV resistant PVC insulation (BS 6746). RAL 5015 (Blue) or RAL 3000 (Red)/RAL 9001 (White)

  3. 3

    Stranding

    Insulations are stranded together.

Technical data

The numbers behind it.

Electrical · 2 x 2 x 0.5 mm

Conductor diameter
0.50 mm
Conductor resistance (20 °C)
93.0 Ω/km
Insulation resistance (@500V DC)
500 MΩ/km
Dielectric strength (DC. 1 minute)
1000 V
Test voltage (@ 1 minute)
1500 V DC

Mechanical

Bending radius
7.5xD mm
Temperature range operating
-30°C ~ +70°C

From the Camcom datasheet. The datasheet for the chosen part number is the reference.

Cable type data

Every size, one part number each.

Camcom part no.Conductor sizeDatasheet
605002UN2 x 2 x 0.5 mmPDF ↓
606002UN2 x 2 x 0.6 mmPDF ↓
608002UN2 x 2 x 0.8 mmPDF ↓