Instrumentation cable
RE-2Y(St)YSWAY-PiMF/TiMF
Available as 45 part numbers from 2 x 2 x 0.50 mm² to 24 x 2 x 2.50 mm². Full construction and technical data are in the datasheet.
Conductor size
Camcom part no.
420552ISP
2 x 2 x 0.50 mm² · 1,000 m
Stock and lead time: ask us by email.
Construction
Eleven layers, from copper out.

- 1
Conductor
Stranded electrolytic copper conductor (Class 2) (IEC 60228, EN 60228, DIN VDE 0295)
- 2
Insulation
Polyethylene (BS EN 50290-2, VDE 0207 YI1), Black, White, Red; Number coded (BS 5308-2)
- 3
Individual stranding
Insulations stranding into pairs or triads
- 4
Individual wrapping
Polyester tape
- 5
Individual screen
Tinned copper earthing wire, Al/PET tape
- 6
Overall stranding
Screened pairs or triads are stranded in layers.
- 7
Overall wrapping
Polyester tape
- 8
Overall screen
Tinned copper earthing wire, Al/PET tape
- 9
Inner jacket
PVC inner jacket. RAL 9005 (Black)
- 10
Armor
Galvanized steel wire armor, polyester tape
- 11
Outer jacket
UV resistant PVC outer jacket. RAL 9005 (Black)
Technical data
The numbers behind it.
Electrical · 2 x 2 x 0.50 mm²
- Conductor diameter
- 0.50 mm²
- Conductor resistance (20 °C)
- 36.0 Ω/km
- Insulation resistance (@500V DC)
- 5000 MΩ/km
- Mutual capacitance
- 160 nF/km
- Operating voltage
- 300/500 V DC
- Test voltage (@ 1 minute)
- 2000 V DC
Values for this size are in its datasheet.
Mechanical
- Bending radius
- 7.5xD mm
- Temperature range operating
- -30°C ~ +70°C
Standards
Manufacturing referance
EN 50288-7 or IEC 60502-1
Flame retardancy test
IEC 60332-1-2
From the Camcom datasheet. The datasheet for the chosen part number is the reference.
Cable type data
Every size, one part number each.
| Camcom part no. | Conductor size | Datasheet |
|---|---|---|
| 420552ISP | 2 x 2 x 0.50 mm² | PDF ↓ |
| 420554ISP | 4 x 2 x 0.50 mm² | PDF ↓ |
| 420556ISP | 6 x 2 x 0.50 mm² | PDF ↓ |
| 420558ISP | 8 x 2 x 0.50 mm² | PDF ↓ |
| 420560ISP | 10 x 2 x 0.50 mm² | PDF ↓ |
| 420562ISP | 12 x 2 x 0.50 mm² | PDF ↓ |
| 420566ISP | 16 x 2 x 0.50 mm² | PDF ↓ |
| 420570ISP | 20 x 2 x 0.50 mm² | PDF ↓ |
| 420574ISP | 24 x 2 x 0.50 mm² | PDF ↓ |
| 420752ISP | 2 x 2 x 0.75 mm² | PDF ↓ |
| 420754ISP | 4 x 2 x 0.75 mm² | PDF ↓ |
| 420756ISP | 6 x 2 x 0.75 mm² | PDF ↓ |
| 420758ISP | 8 x 2 x 0.75 mm² | PDF ↓ |
| 420760ISP | 10 x 2 x 0.75 mm² | PDF ↓ |
| 420762ISP | 12 x 2 x 0.75 mm² | PDF ↓ |
| 420766ISP | 16 x 2 x 0.75 mm² | PDF ↓ |
| 420770ISP | 20 x 2 x 0.75 mm² | PDF ↓ |
| 420774ISP | 24 x 2 x 0.75 mm² | PDF ↓ |
| 421052ISP | 2 x 2 x 1.00 mm² | PDF ↓ |
| 421054ISP | 4 x 2 x 1.00 mm² | PDF ↓ |
| 421056ISP | 6 x 2 x 1.00 mm² | PDF ↓ |
| 421058ISP | 8 x 2 x 1.00 mm² | PDF ↓ |
| 421060ISP | 10 x 2 x 1.00 mm² | PDF ↓ |
| 421062ISP | 12 x 2 x 1.00 mm² | PDF ↓ |
| 421066ISP | 16 x 2 x 1.00 mm² | PDF ↓ |
| 421070ISP | 20 x 2 x 1.00 mm² | PDF ↓ |
| 421074ISP | 24 x 2 x 1.00 mm² | PDF ↓ |
| 421552ISP | 2 x 2 x 1.50 mm² | PDF ↓ |
| 421554ISP | 4 x 2 x 1.50 mm² | PDF ↓ |
| 421556ISP | 6 x 2 x 1.50 mm² | PDF ↓ |
| 421558ISP | 8 x 2 x 1.50 mm² | PDF ↓ |
| 421560ISP | 10 x 2 x 1.50 mm² | PDF ↓ |
| 421562ISP | 12 x 2 x 1.50 mm² | PDF ↓ |
| 421566ISP | 16 x 2 x 1.50 mm² | PDF ↓ |
| 421570ISP | 20 x 2 x 1.50 mm² | PDF ↓ |
| 421574ISP | 24 x 2 x 1.50 mm² | PDF ↓ |
| 422552ISP | 2 x 2 x 2.50 mm² | PDF ↓ |
| 422554ISP | 4 x 2 x 2.50 mm² | PDF ↓ |
| 422556ISP | 6 x 2 x 2.50 mm² | PDF ↓ |
| 422558ISP | 8 x 2 x 2.50 mm² | PDF ↓ |
| 422560ISP | 10 x 2 x 2.50 mm² | PDF ↓ |
| 422562ISP | 12 x 2 x 2.50 mm² | PDF ↓ |
| 422566ISP | 16 x 2 x 2.50 mm² | PDF ↓ |
| 422570ISP | 20 x 2 x 2.50 mm² | PDF ↓ |
| 422574ISP | 24 x 2 x 2.50 mm² | PDF ↓ |