A-02YSF(L)2Yb2Y cable, stripped back to show its construction

Outdoor telephone cable

A-02YSF(L)2Yb2Y

Available as 1 part number. Full construction and technical data are in the datasheet.

Conductor size

Camcom part no.

614000LST

0.40 mm · 1,000 m

Request a quote

Stock and lead time: ask us by email.

Construction

Eleven layers, from copper out.

Cross-section of A-02YSF(L)2Yb2Y
  1. 1

    Conductor

    Electrolytic annealed solid copper (CCITT Yellow Book Vol. III-2-G.541 B article, IEC 28 and ASTM B 3).

  2. 2

    Insulation

    Color coded foam skin polyethylene cladded with solid polyethylene (BS 6234 Type 03 – ASTM D 1248).

  3. 3

    Stranding

    Star quads or pairs are assembled into 10 pairs units. Groups having 25, 50 or 100 pairs are stranded together.

  4. 4

    Filling compound

    Cable core is filled with a special jelly filling compound to avoid the water leakage into air spaces.

  5. 5

    Wrapping

    A non-hygroscopic and dielectric polyester tape is applied on the cable core longitudinally or helically.

  6. 6

    Filling compound

    Secondary jelly filling is applied between wrapping and screen in order to provide waterproofness.

  7. 7

    Screen

    Both sides are coated with copolymer coated flat aluminum tape over cable core longitudinally for screening.

  8. 8

    Inner jacket

    Linear low-density or medium-density, UV resistant black polyethylene inner jacket (ASTM D 1248).

  9. 9

    Filling compound

    A filling compund (Jelly) is applied between inner jacket and armor in order to have waterproofness.

  10. 10

    Armor

    Copolymer coated corrugated steel tape is applied to secure the cable from rodents.

  11. 11

    Outer jacket

    Linear low-density or medium-density, UV resistant black polyethylene outer jacket (ASTM D 1248).

Technical data

The numbers behind it.

Electrical · 0.40 mm

Conductor diameter
0.40 mm
Conductor resistance (20 °C)
139,4 Ω/km
Conductor resistance (20 °C)
146,6 Ω/km
Insulation resistance (500 VDC)
>10000 MΩ/km
Mutual capacitance (800 Hz)
50 nF/km
Mutual capacitance (800 Hz)
56 nF/km
Capacitance unbalance pF/500 m
125
Capacitance unbalance pF/500 m
350
Between adjacent quads – maximum average
125
Between adjacent quads – maximum individual
275
To screen – maximum average
500
To screen – maximum individual
2000
Dielectric strength – (DC, 1 minute)
1400 V
Dielectric strength – (DC, 1 minute)
1400 V
V (DC, 3 second) – pair – screen
9000

From the Camcom datasheet. The datasheet for the chosen part number is the reference.

Cable type data

One part number.

Camcom part no.Conductor sizeDatasheet
614000LST0.40 mmPDF ↓