Signal control cable
LI2YCYSWBY-TP/TT
Stranded copper pairs or triads with a tinned copper braid screen and galvanised steel wire braid armour, sheathed in UV-resistant grey PVC.
Conductor size
Camcom part no.
321050BSQ
1.00 mm² · 1,000 m
Stock and lead time: ask us by email.
Construction
Eight layers, from copper out.

- 1
Conductor
Stranded electrolytic copper, class 5 — IEC 60228, EN 60228, DIN VDE 0295.
- 2
Insulation
Solid polyethylene — EN 50290-2-23, BS 6234 Type 03, ASTM D 1248; colour code DIN 47100.
- 3
Stranding
Cores stranded into pairs or triads; pairs or triads stranded together.
- 4
Wrapping
Polyester tape.
- 5
Screen
Tinned copper braid.
- 6
Inner jacket
UV-resistant PVC, RAL 7035 grey.
- 7
Armour
Galvanised steel wire braid.
- 8
Outer jacket
UV-resistant PVC, RAL 7035 grey.
Technical data
The numbers behind it.
Electrical values below are for 1.00 mm² (321050BSQ). Values for 1.00 mm² are in the 321050BSQ datasheet.
Electrical · 1.00 mm²
- Conductor resistance (20 °C)
- 19.5 Ω/km
- Insulation resistance (20 °C)
- 5000 MΩ·km
- Mutual capacitance
- 130 nF/km
- Operating voltage
- 300/500 V
- Test voltage (1 min)
- 2000 V
Values for this size are in its datasheet.
Mechanical
- Bending radius
- 7.5 × D
- Operating temperature
- −30 °C to +70 °C
- Sheath colour
- RAL 7035 grey
Standards
Flame retardancy
IEC 60332-1-2 · VDE 0482-332-1-2 · BS EN 60332-1-2
Conductor
IEC 60228 · EN 60228 · DIN VDE 0295, class 5