Product image follows. Illustration for reference only.

Building management system cable

4-Pair with 22AWG individual pair shielding PVC Cable

Available as 1 part number. Full construction and technical data are in the datasheet.

Individually screened

Version

Camcom part no.

2354IS

2354IS · 1,000 m

Request a quote

Stock and lead time: ask us by email.

Construction

Nine layers, from copper out.

  1. 1

    Conductor

    22 AWG (7x30) Tinned Copper

  2. 2

    No. of conductors

    8 (4 pairs)

  3. 3

    Insulation

    SR-Polyvinyl Chloride (Semi-Rigid)

  4. 4

    Insulation thickness

    0.011 in (0.28 mm)

  5. 5

    Insulation diameter

    0.051 in (1.3 mm)

  6. 6

    Shield

    Bi-Laminate (Alum+Poly) tape 100% + Tinned Copper braid 65%

  7. 7

    Outer jacket

    Polyvinyl Chloride

  8. 8

    Jacket thickness

    0.045 in (1.1 mm)

  9. 9

    Cable diameter

    0.320 in (8.13 mm)

Technical data

The numbers behind it.

Electrical · 2354IS

Conductor DCR
18.2 Ohm/1000ft
Capacitance Cond-to-Cond
35 pF/ft (110 pF/m)
Capacitance Cond-to-Other
63 pF/ft (210 pF/m)
Velocity of propagation
60%
Max current
2.2 Amps per Conductor at 25°C
Shield DCR
6.2 Ohm/1000ft (20 Ohm/km)
Voltage rating
300 V

Mechanical

Operating temperature
-30°C to +80°C
Min. bending radius
3.2 in (81 mm)
Max. pull tension
72.8 lbs (33.0 kg)
Approx. weight
59 lbs/1000ft

Color & Package

Jacket
PVC
Packing
305 m / 500 m reels or drums

From the Camcom datasheet. The datasheet for the chosen part number is the reference.

Cable type data

One part number.

Camcom part no.VersionDatasheet
2354IS2354ISPDF ↓